61
206-4340
Reference: Power Consumption Settings
The following tables assume that Installer Menu item 118 POWER SAVINGS is set to 3 (default)
and Installer Menu item 099 BACK LIGHTING is set as shown below (default value is 255).
Note: Values are results of controlled experiments under laboratory conditions.
Item 099
Back Lighting
(Static)
32LT570H
43LT570H
49LT570H
Power
Consumption
(Watts)
Percent
Savings
Power
Consumption
(Watts)
Percent
Savings
Power
Consumption
(Watts)
Percent
Savings
100
31.5
0%
55.1
0%
63.1
0%
90
30.1
4%
51.2
7%
58.1
8%
80
29.3
7%
49.0
11%
55.2
13%
70
28.6
9%
47.8
13%
53.6
15%
60
27.8
12%
46.1
16%
51.7
18%
50
27.1
14%
44.1
20%
49.1
22%
40
26.2
17%
41.9
24%
46.6
26%
30
24.3
23%
36.9
33%
40.3
36%
20
21.8
31%
30.7
44%
33.5
47%
10
19.5
38%
24.8
55%
25.5
60%
1
17.4
45%
19.1
65%
18.9
70%
Item 099
Back Lighting
(Dynamic)
32LT570H
43LT570H
49LT570H
Power
Consumption
(Watts)
Percent
Savings
Power
Consumption
(Watts)
Percent
Savings
Power
Consumption
(Watts)
Percent
Savings
200
31.6
0%
54.9
0%
63.3
0%
190
30.1
5%
51.2
7%
58.2
8%
180
29.3
7%
49.1
11%
55.6
12%
170
28.7
9%
47.8
13%
53.6
15%
160
27.9
12%
46.0
16%
51.5
19%
150
27.1
14%
44.0
20%
49.1
22%
140
26.2
17%
41.9
24%
46.7
26%
130
24.3
23%
36.9
33%
40.7
36%
120
21.8
31%
30.5
44%
33.2
48%
110
19.5
38%
24.7
55%
25.7
59%
101
17.3
45%
19.3
65%
19.5
69%