Leveling the Appliance
If the floor is uneven, turn the adjustable feet
as required (Do not insert pieces of wood etc.
under the feet). Make sure that all four feet are
stable and resting on the floor and then check
that the appliance is perfectly level (Use a spirit
level).
•
Once the appliance is level, tighten the lock
nuts up towards the base of the appliance. All
lock nuts must be tightened.
Raise
Lower
Lock nut
Tighten all 4
lock nuts securely
Diagonal Check
•
When pushing down the edges of the top plate
diagonally, the appliance should not move up
and down at all (check both directions). If the
appliance rocks when pushing the machine
top plate diagonally, adjust the feet again.
NOTE
•
Timber or suspended type flooring may
contribute to excessive vibration and
unbalance.
Connecting Supply Hose
•
Water supply pressure must be between 0.1
MPa and 0.8 MPa (100 kPa - 800 kPa).
•
Do not overtighten the water supply hoses.
•
If the water supply pressure is more than 800
kPa, a decompression device or pressure
limiting valve should be installed.
•
Periodically check the condition of the hoses
and replace the hoses if necessary.
Checking the Rubber Seal on the
Supply Hoses
Two rubber seals are supplied with each of the
water inlet hoses. They are used for preventing
water leaks. Make sure the connection to taps is
sufficiently tight. Do not over tighten the hoses
or use any mechanical implements to tighten
them.
Hose connector
Rubber seal
Hose connector
Rubber seal