PERIODIC CHECKS
AFTER THE FIRST 6-12 MONTHS, and then EVERY 6-12 MONTHS:
Clean the salt container following the procedure hereunder:
• Remove the remaining salt from the bottom;
• Clean all the walls of the container from muddy, oozy or dry salt deposits;
• Rinse several times with running water using a disinfectant and a sponge;
• Rinse again, add the same quantity of water and then add the salt.
Periodically clean the washable cartridge of the pre-filter by removing all impurities from the bottom and from
the surface of the cartridge. It is sufficient to use running water.
_________________________________________________________________________________________
TROUBLE SHOOTING
Problems, causes and solutions
PROBLEMS
CAUSES
SOLUTIONS
Regeneration starts at a wrong time
Timer set up incorrectly
Set up the timer
The programmer stops during the
regeneration cycle
Burnt out engine
Replace
Power supply failure
Check connection
Incorrect voltage or frequency
Check the right voltage or frequency
The camshaft is blocked
Remove damaging bodies from the
valve or from the camshaft
Excessive supply pressure
Install a pressure regulator
The programmer does not regenerate
automatically or when the start up
button is pushed
Power supply disconnected
Connect
Damaged or burnt out engine
Replace engine
Burnt out feeder
Replace feeder
Damaged or burnt out timer
Replace timer
The programmer does not regenerate
automatically but only by pushing the
start up button
Too many days between scheduled
regenerations
Reduce amount of days between
regenerations
Burnt motor
Replace motor
Internal gear broken
Replace gear
Water softener
MATIC
with AUTOTROL chronometric head 460TC
14