1.3.3 Operation diagrams
How to read the operating diagram for nitrogen for the
TURBOVAC 850i:
With deploying a SCROLLVAC 7 plus backing pump gas flows may be trans-
ported permanently with maximum throughput quantities of
■
0.2 mbar·l/s (with convection cooling),
■
0.5 mbar·l/s (with air cooling at 40 °C), and
■
approx. 5 mbar·l/s (with cooling water at 35 °C).
These values result of the intersection between the limitations of the individual
cooling variant and the pumping speed of the backing pump given. As can
be seen, maximum permanent gas flows are not solely a TMP characteristic,
but are dependent from the installed backing pump, too.
Gasdurchsatz in mbarl/s
Druck in mbar
Saugleistung TURBOVAC 850i
Kühlwasser 15 °C, 100 l/h
Kühlwasser 35 °C, 50 l/h
Lüfterkühlung 24 °C
Lüfterkühlung 40 °C
Konvektion 24 °C
ECODRY 65 plus
TRIVAC D 65 B
SCROLLVAC 7 plus
DIVAC 3.8 HV3
10
-6
10
-4
10
2
10
-2
1
10
-10
10
-8
10
-6
10
-4
10
10
-2
1
10
-8
Operationsdiagramm
TURBOVAC 850i für Stickstoff
Fig. 1.4 Operation diagram for TURBOVAC 850 i
Operation diagram for
nitrogen for the TURBOVAC 850i
Throughput TURBOVAC 850i
Cooling water 15 °C, 100 l/h
Cooling water 35 °C, 50 l/h
Air cooling 24 °C
Air cooling 40 °C
Convection 24 °C
ECODRY 65 plus
TRIVAC D 65 B
SCROLLVAC 7 plus
DIVAC 3.8 HV3
Gas thr
oughput in mbar·l/s
Pressure in mbar