Profinet
8
300802431_002_C0 - 09/2019 - © Leybold
3 Profinet
ProfiNet module SI-EP3/V (version with one connection)
Settings on the frequency converter
Activating the adapter card
B1-01 = 3
B1-02 = 3
Network parameter
F7-01 to F7-04
IP address
F7-05 to F7-08
Subnet mask
F7-09 to F7-12
Gateway
After setting the parameters, reboot the system.
Note the parameters for later use in the PLC or PC program.
The GSDML file is an xml file that can be downloaded at www.leybold.com
-> Downloads -> Download Software -> PC software for DRYVAC and
RUVAC WH pumps.
Assignment of the PROFINET address
The PROFINET address can only be assigned via the hardware configuration
tool of the PLC. To assign the PROFINET IP address via hardware configura-
tion tool of the PLC, please refer to the documentation of the PLC.
Configuration I/O parameters
The decision to use either the PROFIdrive control and status words or the
Yaskawa-specific control and status words is done in a hardware configura-
tion tool (customer supplied). The default value is the Yaskawa-specific for-
mat.
SI-EP3/V uses slots 0 and 1. Slot 0 does not have any sub-slots and the
attached DAP module represents the device. Other functional modules and
sub-modules described in the GSD file can be assigned to slot 1 and its sub-
slots.
■
Slot 0 = Device access point (DAP)
■
Slot 1, sub-slot 1 = Standard telegram 1, Standard telegram 1 + 5 configu-
rable inputs, outputs, Forty byte IO with 5 configurable input, outputs
The services provided by the SI-EP3/V option can be defined using the
F7-
parameters in the drive or by using a configuration tool. To define the
service using the F7-
parameters, set the parameter to a value other than
0. If all F7-
parameters are set to 0, the value from the configuration tool
will be used.