Ethernet IP
14
300802431_002_C0 - 09/2019 - © Leybold
Input assembly data info
Name
Description
Faulted
Faulted
0: No Faults Occurred
1: Fault Occurred
Warning
Warning
0: No Warning Occurred
1: Warning Occurred
Running 1 (FWD)
Forward Running
0: Stop or Reverse Running
1: Forward Running
Running 2 (REV)
Reverse Running
0: Stop or Forward Running
1: Reverse Running
Ready
Drive Ready
0: Not Ready
1: Ready
Ctrl from Net
Status of Run command from Network
0: Run command is not from network
1: Run command is from network
Ref from Net
Status of Speed reference from Network
0: Speed reference is not from network
1: Speed reference is from network
At Speed
Speed Agree
0: No Speed Agree
1: Speed actual at speed reference
3.4 Error codes
Display
Description
bUS
Option Communication Error
After establishing initial communication, the connection was lost
Only detected when the run command or frequency reference
is assigned to the option (b1-01 = 3 or b1-02 = 3)
EF0
Option Card External Fault
The alarm function for an external device has been triggered.
oFA00
Option Card Fault
Option is not properly connected.
oFA01
Option Card Fault
Option is not properly connected.
oFA03
Option Card Fault
Option self-diagnostics error.
oFA04
Option Card Fault
Option flash write mode.
oFA30
to
oFA43
Communication Option Card Connection Error
Communication ID error
CALL
Serial communication transmission error
Communication is not established.