MPF service check
Action
Yes
No
Step 1
Check the springs, links, and tray guides on the MPF assembly for
damage.
Are they free of damage?
Go to step 2.
Replace the MPF
assembly. See
Step 2
a
Make sure the MPF sensor cable is properly connected to the
controller board.
b
POR into the Diagnostics menu and perform a sensor test:
Diagnostics Menu
>
Input Tray Tests
>
Sensor Tests
>
Multi
‑
Purpose Feeder
Does the sensor state on the control panel display change when
it is toggled?
Go to step 3.
Replace the front
input guide. See
“Front input guide
removal” on
page 248
Step 3
Make sure the MPF pick roller and separator pad are free of debris.
Check both for wear or damage.
Are they free of damage?
Go to step 4.
Replace the MPF
pick roller and
separator pad. See
“MPF pick roller
removal” on
page 242
and
“Separator pad
removal” on
page 250
.
Step 4
a
Remove the left cover.
b
POR into the Diagnostics menu and perform a feed test:
Diagnostics Menu
>
Input Tray Tests
>
Feed Tests
>
Multi
‑
Purpose Feeder
c
Check the MPF solenoid for proper operation.
Does it function properly?
Go to step 5.
Replace the MPF
solenoid. See
Step 5
a
Make sure the MPF gearbox is free of debris.
b
Check the gears and spring of the MPF gearbox for wear or
damage.
Are they free of damage?
Go to step 6.
Replace the MPF
gearbox. See
Step 6
Does the error remain?
Contact the next
level of support.
The problem is
solved.
4514-330
Diagnostics and troubleshooting
102
Summary of Contents for MS312
Page 11: ...Part number index 335 Part name index 339 4514 330 Table of contents 11 ...
Page 12: ...4514 330 Table of contents 12 ...
Page 182: ...4514 330 182 ...
Page 214: ...5 Remove the three screws B and then remove the left front mount B 4514 330 Parts removal 214 ...
Page 230: ...5 Remove the four screws B and then remove the right front mount B 4514 330 Parts removal 230 ...
Page 234: ...b Set the spring over the plunger 4514 330 Parts removal 234 ...
Page 240: ...3 Squeeze the latches B to release the left and right links B 4514 330 Parts removal 240 ...
Page 267: ...11 Disconnect the two springs D D 4514 330 Parts removal 267 ...
Page 284: ...3 Swing the right cover backward to remove 4 Remove the screw D 4514 330 Parts removal 284 ...
Page 286: ...4514 330 286 ...
Page 291: ...4514 330 291 ...
Page 293: ...Assembly 1 Covers 4514 330 Parts catalog 293 ...
Page 295: ...Assembly 2 Electronics 1 1 2 3 4 5 7 8 9 6 4514 330 Parts catalog 295 ...
Page 297: ...Assembly 3 Electronics 2 4 3 2 1 6 5 4514 330 Parts catalog 297 ...
Page 299: ...4514 330 Parts catalog 299 ...
Page 300: ...Assembly 4 Frame 2 5 6 9 10 11 13 14 12 8 1 4 4 3 7 4514 330 Parts catalog 300 ...
Page 302: ...4514 330 Parts catalog 302 ...
Page 303: ...Assembly 5 Option trays 3 4 5 6 1 2 4514 330 Parts catalog 303 ...
Page 306: ...4514 330 Parts catalog 306 ...
Page 308: ...4514 330 308 ...
Page 312: ...4514 330 312 ...
Page 314: ...4514 330 314 ...
Page 326: ...4514 330 326 ...
Page 338: ...4514 330 Part number index 338 ...
Page 342: ...4514 330 Part name index 342 ...