27
Overview of 17D Internal Electronics, continued
General
Characteristics
The Lexium 17D servo drives are available in five peak output current ratings (4.2,
8.4, 16.8, 28 and 56 A) that are partitioned into two groups based on the width of
the package; the 70 mm drives are rated to handle currents up to 28 A and the 120
mm wide drive is rated to handle currents up to 56 A. All Lexium drives operate with
an input voltage which may range from 208 V -10% 60 Hz, 230 V -10% 50 Hz
through 480 V +10% 50-60 Hz.
Each drive provides:
l
Direct shield connection points
l
Two analog setpoint inputs
l
Integrated and electrically isolated RS-232 communications
Primary Power
A single phase input supply may be used for commissioning and set-up and for
continuous operating with various smaller drive/motor combinations. See the
Lexium 17/ BPH motor torque speed curves for details.
Fusing (e.g. fuse cut-out) is provided by the user.
Bias Power
The 17D drive requires 24 Vdc bias power from an external, electrically isolated
supply (SELV).
EMI Suppression
EMI suppression for the 17D drives is integrally provided by filters on both the
primary power (EN550011, Class A, Group 1) input as well as on the 24 Vdc bias
supply (Class A) input.
Continued on next page
Summary of Contents for MHDA1004
Page 1: ...Version 2 0 June 2003 31001643_K01_000_04 Lexium Servo Drive 17D Series User Guide...
Page 2: ......
Page 4: ...Preface iv 890 USE 120 00...
Page 14: ...Contents xiv 890 USE 120 00...
Page 28: ...14...
Page 46: ...32...
Page 56: ...42...
Page 112: ...Chapter 5 System Operation 98 890 USE 120 00...
Page 130: ...116 Continued on next page...
Page 148: ...134...
Page 172: ...158...
Page 198: ...184...
Page 204: ...Index 190 890 USE 120 00...