Wire Specifications (Recommended)
Wire
Specifications
The following table lists the recommended wire specifications. Use only copper
wire with insulation rated at 75
°
C or greater, unless otherwise specified.
Item
Drive Model No.
Wire Size
Notes
AC mains
MHDA1004•00
MHDA1008•00
MHDA1017•00
MHDA1028•00
1.5 mm
2
or 14 AWG
600V, 105°C
MHDA1056•00
4.0 mm
2
or 10 AWG
Protective earth
All
4.0 mm
2
or 10 AWG
DC Link
MHDA1004•00
MHDA1008•00
MHDA1017•00
MHDA1028•00
1.5 mm
2
or 14 AWG
Shielded for lengths
greater than 20cm
1000V , 105°C
MHDA1056•00
4.0 mm
2
or 10 AWG
Analog signals
All
0.25 mm
2
or
22 AWG minimum
Twisted pairs,
shielded
Digital I/O and Fault
Relay
All
0.5 mm
2
or
20 AWG minimum
Brake
All
1.0 mm
2
or
16 AWG minimum
Shielded
Bias power 24 Vdc
All
2.5 mm
2
or
14 AWG maximum
External Regen
resistor
All
1.5 mm
2
or 14 AWG
High temperature
insulation 1000V,
105°C or greater
Summary of Contents for MHDA1004