124
Electrical Specifications - Signal, continued
Analog Input
Specifications
Table
The following table lists the analog inputs specifications.
Analog Output
Specifications
Table
The following table lists the analog output specifications.
Continued on next page
ANALOG INPUTS
Channels
Two
Type
Differential, non–isolated
Maximum common mode
voltage referenced to AGND
±10V
Measurement range
±10 Vdc
Maximum differential input
±12 V
Accuracy
12 bits
Resolution
Input 1 = 14 bits (±10V range)
Input 2 = 12 bits (±10V range)
Input impedance
20 k
Ω
Scan time
250
µ
s
ANALOG OUTPUTS
Channels
Two
Type
Single-ended, non-isolated
referenced to AGND
V
OUT
± 10 V
I
OUT
± 5 mA
Output impedance
2.2 k
Ω
Maximum load capacitance
0.1
µ
F
Resolution
10 bits
Update time
5 msec