Parameter
Rated data
Units
Model Number
(prefix with MHDA10)
04
p
00
08
p
00
17
p
00
28
p
00
56
p
00
Supply Voltage
3
phase
,
230 V
Upper switch-on level of Regen circuit
V
400 - 430
Switch-off level of Regen circuit
V
380 - 410
Overvoltage F02
V
450
Continuous power of Regen circuit (RBint)
W
80
200
Continuous power of Regen circuit (RBext) max.
kW
0.25
0.75
Pulse power, internal (RBint max. 1s)
kW
2.5
5
Pulse power, external (RBext max. 1s)
kW
5
3 phase
,
400 V
Upper switch-on level of Regen circuit
V
720 - 750
Switch-off level of Regen circuit
V
680 - 710
Overvoltage F02
V
800
Continuous power of Regen circuit (RBint)
W
80
200
Continuous power of Regen circuit (RBext) max.
kW
0.4
1.2
Pulse power, internal (RBint max. 1s)
kW
8
16
Pulse power, external (RBext max. 1s)
kW
16
3 phase
,
480 V
Upper switch-on level of Regen circuit
V
840 - 870
Switch-off level of Regen circuit
V
800 - 830
Overvoltage F02
V
900
Continuous power of Regen circuit (RBint)
W
80
200
Continuous power of Regen circuit (RBext) max.
kW
0.5
1.5
Pulse power, internal (RBint maximum 1s)
kW
10.5
21
Pulse power, external (RBext maximum 1s)
kW
21
Internal Regen resistor
Ω
66
33
External Regen resistor
Ω
33
Summary of Contents for MHDA1004
Page 1: ...Version 2 0 June 2003 31001643_K01_000_04 Lexium Servo Drive 17D Series User Guide...
Page 2: ......
Page 4: ...Preface iv 890 USE 120 00...
Page 14: ...Contents xiv 890 USE 120 00...
Page 28: ...14...
Page 46: ...32...
Page 56: ...42...
Page 112: ...Chapter 5 System Operation 98 890 USE 120 00...
Page 130: ...116 Continued on next page...
Page 148: ...134...
Page 172: ...158...
Page 198: ...184...
Page 204: ...Index 190 890 USE 120 00...