102
Error Messages, continued
Error
Identification
and Description,
continued
Continued on next page
Error
Code
Error (Fault)
Possible Cause/Corrective Action
F06
Motor overtemperature.
- I
rms
or I
peak
set too high.
- Defective motor
- If motor is not hot, check feedback cables and
connectors.
- Reduce motion profile duty cycle
- Improve ventilation of the motor
F07
Internal 24 Vdc fault.
Return drive to manufacturer
F08*
Motor speed limit
exceeded.
- Feedback parameters not set correctly.
- Incorrect feedback wiring.
- Motor phases reversed.
- Check Parameter “Overspeed” for correct setting.
F09
EEPROM checksum error. Return drive to manufacturer.
F10
Flash-EPROM checksum
error.
Return drive to manufacturer.
F11
Motor brake fault.
- Brake parameter set to “WITH” when brake does not
exist.
- Defective brake.
- Check motor power cable and connections.
F12
Motor phase missing.
- Defective motor.
- Check motor power cable and connections
F13*
Drive internal temperature
exceeded.
- Improve ventilation.
- Reduce motion profile duty cycle.
Summary of Contents for MHDA1004
Page 1: ...Version 2 0 June 2003 31001643_K01_000_04 Lexium Servo Drive 17D Series User Guide...
Page 2: ......
Page 4: ...Preface iv 890 USE 120 00...
Page 14: ...Contents xiv 890 USE 120 00...
Page 28: ...14...
Page 46: ...32...
Page 56: ...42...
Page 112: ...Chapter 5 System Operation 98 890 USE 120 00...
Page 130: ...116 Continued on next page...
Page 148: ...134...
Page 172: ...158...
Page 198: ...184...
Page 204: ...Index 190 890 USE 120 00...