Connection mode one:
Warning!
Connection mode two:
AC
L
L’
N
AC
L
L’’
N
Connect N, L with power;Connect N, L’’ with load.
Connect the load to L’’, the load will work
,
when signal detected ,the load stop working.
Connect N, L with power;Connect N, L’ with load.
Connect the load to L’, the load will work when signal detected and will stop
working over the preset delay-time when there are no following signals.
Applications
Microwave can penetrate the glass, plastic and wood, thus the microwave sensor can be installed inside the
shade made of certain thickness of glass, plastic or wood. For example, the application in lightings, only if
making connection as below shown can you change the common lightings into auto-sensing lightings.
The above application inside the lightings is one of multiple practical utilizations. You can also install one or more inside
the ceiling or floor to control the whole passageway.
Friendly reminder: when installing two or more microwaves together, you are required to keep 4 meters one from
another, otherwise the interference among them will lead to error reaction.
Nonmetals
When installed inside the ceiling or floor, the microwave sensor
fails to distinguish the ambient light intensity automatically.
Microwave will be reflected by the metal, thus
the microwave sensor cannot be installed
inside the shade made of metal, or it won’t
work normally.
2.5-4.5m
360º
Min:1m
Min:1m
Max:11m
Max:11m
Height of installation2.5-4.5m
Sensing angle adjustment range
Sensing distance adjustment range
Sensor information