5. MODE Switch

(continued from page 2-5)

Make sure the amplifier is powered off when the MODE switch
setting is changed.

INPUTs and OUTPUTs used in (BRIDGED) mode are labelled in
parenthesis. Do not use other INPUTs and OUTPUTs that are
not labelled in parenthesis. Connect the positive speaker lead
to the positive (red) OUTPUT of the first channel, and
connect the negative speaker lead to the positive (red)
OUTPUT of the second channel.

6. UNBAL/BAL Switch

Selects between unbalanced (RCA) or balanced (XLR, tip/ring/
sleeve) audio input for each channel. Power the amplifier off or
reduce system volume before changing the setting of the
UNBAL/BAL switch.  If the amplifier is connected to a digital
controller such as the MC-12 or MC-8, output levels should be
re-calibrated whenever the setting is changed.

7. GROUND LIFT Switch

When set to ON, isolates the ground connection between the
audio inputs and the chassis. This can be useful for
eliminating audible hum or noise caused by multiple
grounding paths in the system. When set to OFF, the audio
inputs are grounded to the chassis. This switch should be set to
ON whenever there is ground noise present in the system.

8. TRIGGER INPUT

Enables the amplifier to be controlled by the MC-12/MC-8 or
other external devices with a 12V DC trigger output. Connect
the trigger output of the external device to the TRIGGER INPUT
of the amplifer, and set the TRIGGER switch on the amplifier to
ON or DELAY. The amplifier will automatically respond when
the external device is powered on and off.

9. TRIGGER INPUT Switch

When set to OFF, the amplifier only powers on and off in
response to the front panel standby button. When set to ON
or DELAY, only the external device connected to the TRIGGER
INPUT can be used to power the amplifier on and off. The front
panel standby button will not power the unit on and off.
(However, the standby LED still functions normally.)  When  set
to DELAY, the normal 5 second power on delay is extended to
approximately 7 seconds. 

The TRIGGER INPUT Switch setting will not take effect until the
amplifier has been power cycled.

Do not defeat or remove the ground prong on the AC
power cord. This will result in a safety hazard, and will not
reduce audible hum. The GROUND LIFT switch has no
effect on the safety ground of the amplifier.

WARNING

Summary of Contents for LX - REV 3

Page 1: ...LX Power Amplifier User Guide...

Page 2: ...nched particularly at plugs convenience receptacles and the point where they exit from the apparatus 12 Only use attachments accessories specified by the manufacturer 13 Use only with a cart stand bra...

Page 3: ...ocedure practice condition or the like that if not correctly performed or adhered to could result in damage to or destruction of part or all of the product Note Calls attention to information that is...

Page 4: ...ection 1 Getting Started About the LX Power Amplifiers 1 2 Highlights Product Registration 1 3 Installation Considerations 1 3 Section 2 Basic Operation Front Panel Overview 2 2 Rear Panel Overview 2...

Page 5: ...condensando los materiales para las se ales de da o Informe cualquier da o en seguida al portador el funcionamiento defectuoso de equipo de informe a su distribuidor D BALLER ET INSPECTI N Apr s avoi...

Page 6: ...1 Getting Started About the LX Power Amplifiers 1 2 Highlights Product Registration 1 3 Installation Considerations 1 3...

Page 7: ...LX amplifiers to be controlled with associated components such as the MC 12 or MC 8 Digital Controller In addition a ground lift switch can be used to eliminate audible hum caused from multiple groun...

Page 8: ...hannel Bridgeable architecture for higher power output 400W at 8 Oversized toroidal power transformer with extraordinarily low DC resistance and thermal protection High power supply voltage 160V for e...

Page 9: ...2 Basic Operation Front Panel Overview 2 2 Rear Panel Overview 2 4 Cooling System 2 8 Protection Modes 2 8 Thermal Protection DC Protection...

Page 10: ...deactivates the LX amplifier When the unit is in standby pressing the standby button deactivates standby mode and activates the LX amplifier The red standby button LED will flash for approximately fiv...

Page 11: ...rmal Operation Constant Bright Blue 1 distortion in the audio signal Reduce vol ume level to help eliminate potentially damaging audio signals from reaching the speakers Flashing Red The temperature o...

Page 12: ...s shown on page 2 6 The rear panels are similar except the LX 7 amplifier includes two additional channels 1 8 9 3 6 4 5 2 7 External wiring connected to connectors marked with the triangle pictured a...

Page 13: ...ed voltage may cause the amplifier to enter a protection mode indicated by the red standby LED flashing 3 INPUT 1 to 7 LX 7 or 1 to 5 LX 5 Provide audio input for the speakers connected to the corresp...

Page 14: ...7 rear panel is shown on page 2 4 Both are similar except the LX 7 features two additional channels 1 8 9 3 6 4 5 2 7 External wiring connected to connectors marked with the triangle pictured at the...

Page 15: ...the audio inputs are grounded to the chassis This switch should be set to ON whenever there is ground noise present in the system 8 TRIGGER INPUT Enables the amplifier to be controlled by the MC 12 M...

Page 16: ...ansistor reaches its maximum allowable temperature it is instantly restrict ed until the temperature decreases JTS s dynamic nature enables it to avoid the problems inherent in competing products that...

Page 17: ...the corresponding front panel channel status LED will no longer be lit After approximately 4 seconds DC protection will be automatically deactivated The relay will close and the corresponding channel...

Page 18: ...3 Troubleshooting Maintenance Troubleshooting 3 2 Maintenance 3 3...

Page 19: ...wer switch is set to on 2 Make certain the rear panel TRIGGER INPUT switch is set to OFF One or more channels is not passing audio but the corresponding channel status LED is lit blue 1 Make sure the...

Page 20: ...xicon com for answers to frequently asked questions and additional troubleshooting information MAINTENANCE The following routine maintenance should be performed on a periodic basis Clean the exterior...

Page 21: ...A Appendix Specifications A 2 Declaration of Conformity A 4...

Page 22: ...ormance Minimum 2 INDIVIDUAL Mode Speaker 4 BRIDGED Mode Impedance Performance Continued Frequency 20Hz to 20kHz 0 1dB Response 10Hz to 100kHz 0 5 3dB THD Below 0 02 at 200W 8 all channels driven 20Hz...

Page 23: ...s A 3 Other Continued Weight LX 7 LX 5 56lbs 25 4kg 52lbs 23 6kg Rack Mounting Optional brackets are available for mounting either amplifier in stan dard 9 inch equipment rack Specifications are subje...

Page 24: ...d EN 60065 1998 Manufacturer Lexicon Inc 3 Oak Park Bedford MA 01730 1441 USA The equipment identified here conforms to the Directive s and Standard s specified above Type of Equipment LX 5 and LX 7 P...

Page 25: ...to 1 3 Maintenance 3 3 Male Cable End XLR 2 5 Illustration MODE Switch 2 5 2 7 3 2 OUTPUTs 2 4 2 5 2 6 2 7 2 8 2 9 Power Outage 3 3 Power Switch 2 5 3 2 Product Registration 1 3 Protection Modes 2 8...

Page 26: ...on about where the unit should be taken or sent When making a written request please include your name complete address and daytime telephone number the product model and serial numbers and a descript...

Page 27: ...nc 3 Oak Park Bedford MA 01730 1413 USA Tel 781 280 0300 Fax 781 280 0490 www lexicon com Customer Support Tel 781 280 0300 Fax 781 280 0495 Sales Fax 781 280 0499 Service Lexicon Part No 070 14876 Re...

Reviews: