background image

PowerGATE

400A - 800A

Input / Output Panels  

User Manual

Switches & Panels

PowerGATE™

A safe, convenient and 

reliable way to connect 

and access temporary 

power

LM-PIP400

Summary of Contents for PowerGATE 400A

Page 1: ...PowerGATE 400A 800A Input Output Panels User Manual Switches Panels PowerGATE Asafe convenientand reliablewaytoconnect andaccesstemporary power LM PIP400...

Page 2: ...presented Model Numbers and Ratings Important Contact Lex Products 800 643 4460 info lexproducts com 2 PowerGATE Power Input Output Panel This manual contains information critical to the proper instal...

Page 3: ...selected to allow convenient connection to a generator or load bank and located a suitable distance away from any building openings or HVAC inlets Proper clearance must be allowed in front of the Pow...

Page 4: ...try standard Cam type connections for rapid termination Integral mounting brackets secure the panel to the building Padlock handle prevents unauthorized access Low profile aluminum enclosure is only 1...

Page 5: ...2 Installing the Conduit NOTE Conduit to enter through the top of the device See Figure 5 PowerGATE Power Input Output Panel NOTE To maintain TYPE 3R Rating compliance for the enclosure proper sealin...

Page 6: ...ork properly if the phases are connected in the correct order Some motors may work when connected improperly but will operate backwards Utility power and electrical generators may be wired either in a...

Page 7: ...ded starting PowerGATE Power Input Panel Set up Figure 9 C Rotate cam connector jacket clockwise until it stops 4 Complete the Neutral white connection Proper connection See Figure 9 A Grasp connector...

Page 8: ...ll on connector until it separates from the plug C Set aside 3 Continue with ALL Phase hot connections 4 Complete disconnect of ALL hot connections prior to proceeding 5 Disconnect the Neutral white c...

Page 9: ...p 3 Tighten terminal screws to 375 lb in torque each 4 If metallic conduit is used connect ground wire from ground bushing on conduit to the ground connection point in the upper right quadrant of the...

Page 10: ...mly pull on connector until it separates from the plug C Set aside 6 Disconnect the Ground green connections Proper disconnection See Figure 10 A Grasp connector jacket firmly and rotate cam connector...

Page 11: ...inside of the door panel Apply provided UL50 50E sealant to the kirk key shoulder where it will meet and seal with the inside of the enclosure door Form a complete circular ring around the shoulder in...

Page 12: ...d Do not use cable if connectors or plug do not seat properly Do not use cables if any copper wiring is exposed 6 Lex Products technical services are available to assist in resolving issues If you hav...

Page 13: ...er Input Output Panel Appendix B Figure 11 Appendix C Replacement Cable Plate Replacement Part Number 20230 1 809 4 Description Cable Lock Plate 4 Wire 400 800A PGIP Replacement Part Number 20230 1 80...

Page 14: ...Contact Lex Products 800 643 4460 info lexproducts com 14 PowerGATE Power Input Panel Appendix D Labels for Replacement Input Panel...

Page 15: ...Contact Lex Products 800 643 4460 info lexproducts com 15 PowerGATE Power Output Panel Appendix D Labels for Replacement Output Panel...

Page 16: ...vironmental Rating TYPE 3R Rainproof Input 1 Set of 5 Panel Mount 16 Series Cam type Inlets Color coded 1 Dual Port Aluminum Lug per Phase Neutral Ground Wire Range 600 MCM 2 AWG Output 1 Dual Port Al...