PUFP-CT-WC SERIES INSTALLATION GUIDE
FOR PART NUMBERS:
PUFP-CT-B-WC, PUFP-CT-BK-WC, PUFP-CT-DB-WC, PUFP-CT-
OW-WC, PUFP-CT-NS-WC, PUFP-CT-SS-WC , PUFP-CT-B-20A-2USB-WC, PUFP-CT-BK-
20A-2USB-WC, PUFP-CT-DB-20A-2USB, PUFP-CT-OW-20A-2USB-WC , PUFP-CT-NS-
20A-2USB-WC, PUFP-CT-SS-20A-2USB-WC
PRIOR TO INSTALLATION:
1. To ensure compliance with local electric codes, please contact your local
electrical inspector prior to installation
2. Do not install PUFP-CT-WC prior to electrical inspector authorization.
3. Installation should only be done by a licensed and bonded electrical contractor.
4. All power must be turned off at its source prior to installation. Failure to do so
may result in injury or death.
5. If anytime water enters into the PUFP-CT-WC, turn off power at its source and
have the unit replaced by a licensed and bonded electrical contractor.
6. All PUFP-CT-20A-2USB-WC are supplied with dust covers for the USB ports.
These dust covers must remain inside the USB openings UNLESS the port(s) is in
use. Failure to do so will void any ETL listing.
7. All PUFP-CT-WC include a 20 amp cord/plug. Under no circumstances should the
cord be cut and the unit hard wired. This will void any ETL listing and any warranty
provided by Lew Electric.
8. All
NON GFCI PUFP-CT-WC
series must be connected to a GFCI circuit breaker.
Failure to do so will increase the risk of injury.
LEW ELECTRIC ACCEPTS NO RESPONSIBILITY IF THE ABOVE CONDITIONS ARE
NOT MET.
REQUIRED TOOLS:
-Construction Adhesive, Crimpling Pliers/ Wire Strippers, Philips Head Screw
Driver, and Drill.
INSTALLATION (Part One):
1. Prior to installation, a professional granite cutter should cut a 4 1/16” x 4 1/16”
hole in the desired location of the PUFP-CT.
2. Always use the supplied PUFP-WB stamped steel box
3. The tabs on the side of the PUFP-WB box must be attached to the BOTTOM of the
countertop. Please note that the PUFP-CT will not work if the tabs are mounted on
the top of the counter.