User Manual for PuraLev
®
2000SU
www.levitronix.com
PL-4034-00, Rev02, DCO# 20-144
3
1
Safety Precautions
The
PuraLev
®
2000SU
pump system is designed to be used in industrial production machines and
equipment containing hydraulic circuits. Typical applications are Pharmaceutical and Bioprocessing
equipment. Installation shall be done by qualified personnel only. Following safety precautions and all
“CAUTION”, “WARNING” and “DANGER” indications in the relevant sections shall be followed.
CAUTION
Do not under any circumstances open the controller or motor. Levitronix
®
does not
assume responsibility for any damage, which occurs under such circumstances.
CAUTION
High magnetic field strength of pump impeller.
The pump system contains a rotor magnet with high field strength. This may alter
or damage the calibration of sensitive electronic devices and measuring
instruments in the immediate surroundings. Keep at a safe distance from the rotor,
computers, monitors and all magnetic data storage media (e.g. disks, credit cards,
audio, video tapes etc.)
!
WARNING
Hazardous voltage may be present.
The controller must be grounded and placed in a spill protected electrical cabinet.
Do not under any circumstances open the powered controller.
Always isolate the electrical power supply before making or changing connections
to the unit. To remove the power it is recommended to use an isolating device.
Hazardous voltage is present until 20 sec after switch off. Do not handle the
controller during this time.
!
WARNING
High magnetic field strength of pump impeller.
The pump system contains a rotor magnet with high field strength. Pace maker
may be influenced and magnetic forces may lead to contusions. Keep distance to
pace makers and handle impeller with care.
!
WARNING
TOXIC CHEMICALS may be present.
When using the system to pump chemicals skin contact and toxic gases may be
hazardous to your health. Wear safety gloves and other appropriate safety
equipment.
!
WARNING
Motors for ATEX / IECEx applications: only specific types of motors LPM-2000 are
classified for the use in ATEX Zone 2 classified locations. Refer to the
corresponding section in the manual.
!
WARNING
Do not miss-match the power extension cables for connection of the motor to the
controller of the BPS-
4 pump system with the one’s of the PuraLev
®
2000SU
as
this may destroy the controller. The BPS-4 power extension cables are designated
with “MCAP-4.x” and the one’s of the PuraLev
®
2000SU
with “MCAP-2000.x”.