![Levitronix PLD-iF30SU.1 User Manual Download Page 20](http://html.mh-extra.com/html/levitronix/pld-if30su-1/pld-if30su-1_user-manual_1886605020.webp)
User Manual for PuraLev
®
iF30SU
www.levitronix.com
PL-4078-00, Rev00, DCO# 20-228
20
4.2 Electrical Installation of EasyConnect Model
4.2.1 Overview of Connections and Designations
Figure 21: Electrical connections to EasyConnect flow control driver IFD-30.4
Pin #
Pin
Name
Wire
Color
1
Description
Standard
Designation
2
Specifications
Typical Levels
Note
2
P +
red
+ 24 VDC
Power Supply
Voltage: 24 VDC ±10%
Power: 35 W
“P -“ shall be connected to earth
1
P -
black
Ground/Earth
3
NC
white
Not connected
--
Wire of compatible cables is cut.
Wire of compatible cables is cut.
Table 11: Power supply connector of EasyConnect driver
Note 1: Wire colors of compatible cables: ICP-1.1-xx. Note 2: Designations for standard firmware. For other firmware refer to relevant documentation.
Pin #
1
Pin
Name
Wire
Color
1
Description
Standard
Designation
Typical Levels
Note
3
GND
brown
Ground
--
--
--
black
shield
6
NC
pink-blue
Not connected
--
--
--
1
RS485+
white
RS485+
Fieldbus
Modbus RTU protocol.
For remote control with other devices.
Usage of
Levitronix Service Software
with a
RS485 to USB adaptor cable (see
2
RS485-
yellow
RS485-
4
Internal
grey
Internal
Do not
connect.
--
Internal bus needed to connect pumps for serial
pumping.
5
Internal
red
Internal
Table 12: Fieldbus IN connector of EasyConnect driver
Note 1: Screw type connector pin out and wires of compatible cables: ICS-1.1-xx and ICS-1.2-xx.
Pin #
1
Pin
Name
Wire
Color
1
Description
Standard
Designation
Typical Levels
Note
3
GND
brown
Ground
Supply
Output
24VDC ±10%, 200 mA max.
(Max. current is together with Pout of
PLC
connector in
For supply of external devices (displays etc.).
Internally protected.
black
shield
6
Pout
pink-blue
Output 24VDC
1
RS485+
white
RS485+
Fieldbus
Modbus RTU protocol.
For remote control with other devices.
Usage of
Levitronix Service Software
with a
RS485 to USB adaptor cable (see
).
Feed through for system arrays.
2
RS485-
yellow
RS485-
4
Internal
grey
Internal
Do not
connect.
--
Internal bus needed to connect pumps for serial
pumping.
5
Internal
red
Internal
Table 13: Fieldbus OUT connector of EasyConnect driver
Note 1: Screw type connector pin out and wires of compatible cables: ICS-1.1-xx and ICS-1.2-xx.
Power Supply
Connector
PLC 12 Connector
Fieldbus IN
Fieldbus OUT