background image

Single Pole (One location) or 3-Way (Multi-location)

Electronic Low-Voltage Dimmer (Lighted)

Cat. No. VZEØ4-1L, 400W

Cat. No. VZEØ6-1L, 600W

120VAC, 60Hz

InstaLLatIon InstructIons

WarnInGs anD cautIons

:

•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult a qualified electrician.
•  To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.
•  Use with electronic low-voltage transformers only. Do Not use to control a magnetic low-voltage transformer. Use a Leviton magnetic low-voltage dimmer to control magnetic
  low-voltage transformers.
•  This dimmer provides protection from overheating. An excessive load applied to the dimmer will cause the dimmer to overheat. The excess load must be removed to resume proper 

operation.

•  Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.
•  Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn the light on 

at the brightness level selected at the dimmer.

WarnInGs anD cautIons

:

•  Lighting fixture and dimmer must be grounded.
•  This dimmer must be installed in a wall box with a neutral connection.
•  Consult fixture manufacturer to determine if their solid state transformers can be dimmed.
•  Total minimum load must exceed 40W.
•  Dimmer may feel warm to the touch during normal operation.
•  Recommended minimum wall box depth is 2-1/2".
•  Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.

IMPORTANT :

 For 3-Way applications, note that one of the screw 

terminals from the old switch being removed will usually be a different 

color (Black) or labeled Common. Tag that wire with electrical tape and 

identify as the common (Line or Load) in both the dimmer wall box and 

remote wall box.

For non-standard wiring applications, refer

to Wire nut and connector size chart

1 - #12 w/ 1 to 3 #14, #16 or #18

2 - #12 w/ 1 or 2 #16 or #18

1 - #14 w/ 1 to 4 #16 or #18

2 - #14 w/ 1 to 3 #16 or #18

WIrE connEctor / # oF conD.

coMBInatIon cHart

PK-93392-10-00-2C

MaXIMuM LoaD PEr DIMMEr For MuLtI-DEVIcE

cat. no.

VZEØ4
VZEØ6

single

400W
600W

two Devices

350W
500W

More than 

2 Devices

250W
400W

 tools needed to install your Dimmer:

Slotted/Phillips Screwdriver 

Electrical Tape

Pliers 

 

 

Pencil

Cutters 

 

 

Ruler

Typically, removal of the side sections in multi-dimmer installations 

requires a reduction of the dimmer’s capacity. Refer to the chart for 

maximum load per dimmer.

remove all 

inner side 

sections

Bend back 

and forth to 

remove side 

section

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

cut 

(if necessary)

5/8" 

(1.6 cm)

strip Gage (measure 

bare wire here)

Preparing and connecting wires:

Pull off pre-cut insulation from dimmer leads. Make sure that 

the ends of the wires from the wall box are 

straight (cut if 

necessary)

. Remove insulation from each wire in the wall 

box as shown:

•  For single-Pole application, go to step 4a.

•  For 3-Way coordinating remote (no LEDs) application, go to step 4b.

•  For 3-Way Matching remote (with LEDs) application, go to step 4c.

Dimmer

Insulating

Label

Black

Primary

Side

Electronic

Low-Voltage
Transformer

Hot (Black)

Black

Line

120VAC, 60Hz

Neutral (White)

Red

Yellow/Red

White

White

Green

Ground

WIrInG DIMMEr:

connect wires per WIrInG DIaGraM as follows:

•  Green or bare copper wire in wall box to Green dimmer lead.

•  Line Hot wall box wire to Black dimmer lead.

•  Load wall box wire to Red dimmer lead.

•  Line Neutral wall box wire to White dimmer lead.

•  Yellow/Red wire should have Red insulation label affixed. 

 

notE:

 If insulating label is not affixed to Yellow/Red dimmer lead, 

use electrical tape to cover.

• 

Proceed to step 5.

Hot (Black)

Neutral (White)

Dimmer

Coordinating Remote (no LEDs)

YL/RD

Yellow/Red

RD

White

Red

Black

Black

BK

WH

White

Line 

120VAC, 60Hz

Green

Ground

Green

Ground

Electronic

Low-Voltage
Transformer

Primary

Side

(unused)

(unused)

WIrInG DIMMEr:

connect wires per WIrInG DIaGraM as follows:

notE:

 The dimmer must be installed in a wall box that has a Line 

Hot connection.

notE:

 Maximum wire length from dimmer to all installed remotes 

cannot exceed 300 ft (90 m).

•  Green or bare copper wire in wall box to Green dimmer lead.

•  Line Hot (common) wall box wire identified (tagged) when 

removing old switch to Black dimmer lead.

•  First Traveler wall box wire to Red dimmer lead 

(note wire color)

.

•  Remove Red insulating label from Yellow/Red dimmer lead.

•  Second Traveler wall box wire to Yellow/Red dimmer lead 

(note 

wire color)

. This traveler from the dimmer must go to the terminal 

screw on the remote marked "YL/RD".

•  Line Neutral wall box wire to White dimmer lead.

WIrInG coorDInatInG rEMotE:

connect wires per WIrInG DIaGraM as follows:

notE:

 "BK" and "RD" terminals on coordinating remote are unused.  

Tighten both screws.

notE:

 Maximum wire length from dimmer to last remote is 

300 ft (90 m).

•  Green or bare copper wire in wall box to Green terminal screw.

•  Load wall box wire identified (tagged) when removing old switch 

to First Traveler 

(note color as above)

.

•  Second Traveler wall box wire 

(note color as above)

 to terminal 

screw marked "YL/RD". This traveler from the remote must go to 

the Yellow/Red dimmer lead.

•  Remove White insulating label from terminal screw marked "WH". 

•  Line Neutral wall box wire to terminal screw marked "WH".

• 

Proceed to step 5.

InstaLLInG Your DIMMEr

notE:

 Use check boxes           when Steps are completed.

2

4

3

1

2

4

1

5

3

single Pole
1.

 Line (Hot)

2.

 Neutral

3.

 Ground

4.

 Load 

3-Way
1.

 Line or Load 

(see important instruction below)

2.

 Neutral

3.

 Ground

4.

 First Traveler – note color

5.

 Second Traveler – note color. 

notE:

 For 

matching remote w/LEDs installation, the 

First traveler

 becomes Line Hot.

MuLtI-DEVIcE aPPLIcatIon

In multi-device installations, the side sections of the mounting straps 

may require removal. Use pliers to carefully bend side sections back 

and forth until they break off.

If installing Dimmer in a single device application, proceed with the 

InstaLLInG Your DIMMEr

 section. If installing Dimmer in a 

multi-device application, proceed as follows:

 Installing Dimmer by itself or with other devices:

changing the color of your Dimmer:

Your Dimmer includes three color options. The Dimmer ships with the 

White frame attached. To change color of frame, proceed as follows:

Push in side at 

tab to release

Line up tabs and 

press in side to attach

WarnInG: 

to aVoID FIrE sHocK or DEatH; turn 

oFF PoWEr 

at circuit breaker or fuse and test that power 

is off before wiring!

 

step 1

Identifying your wiring application 

(most common):

notE:

 If the wiring in your wall box does not resemble any 

of these configurations, consult a qualified electrician.

 

step 2

 

step 3

single Pole Wiring application:

Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove
this insulating label.

1

4

Black

White

Green

Red

Yellow/Red

2

3

 

step 4a

 

step 4a cont'd

Coordinating Remote

Dimmer

BK

WH

YL/RD RD

5

1

4

5

Green

Yellow/
Red

Red

Black

White

2

1

4

3

2

3

3-Way Wiring with coordinating Dimming or 

switching remote (no LEDs) application:

(coordinating Dimming remote depicted)

 

step 4b

 