Single Pole (One location) or 3-Way (Multi-location)
Electronic Low-Voltage Dimmer (Lighted)
Cat. No. VZEØ4-1L, 400W
Cat. No. VZEØ6-1L, 600W
120VAC, 60Hz
InstaLLatIon InstructIons
WarnInGs anD cautIons
:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.
• Use with electronic low-voltage transformers only. Do Not use to control a magnetic low-voltage transformer. Use a Leviton magnetic low-voltage dimmer to control magnetic
low-voltage transformers.
• This dimmer provides protection from overheating. An excessive load applied to the dimmer will cause the dimmer to overheat. The excess load must be removed to resume proper
operation.
• Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.
• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn the light on
at the brightness level selected at the dimmer.
WarnInGs anD cautIons
:
• Lighting fixture and dimmer must be grounded.
• This dimmer must be installed in a wall box with a neutral connection.
• Consult fixture manufacturer to determine if their solid state transformers can be dimmed.
• Total minimum load must exceed 40W.
• Dimmer may feel warm to the touch during normal operation.
• Recommended minimum wall box depth is 2-1/2".
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
IMPORTANT :
For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a different
color (Black) or labeled Common. Tag that wire with electrical tape and
identify as the common (Line or Load) in both the dimmer wall box and
remote wall box.
For non-standard wiring applications, refer
to Wire nut and connector size chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIrE connEctor / # oF conD.
coMBInatIon cHart
PK-93392-10-00-2C
MaXIMuM LoaD PEr DIMMEr For MuLtI-DEVIcE
cat. no.
VZEØ4
VZEØ6
single
400W
600W
two Devices
350W
500W
More than
2 Devices
250W
400W
tools needed to install your Dimmer:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Typically, removal of the side sections in multi-dimmer installations
requires a reduction of the dimmer’s capacity. Refer to the chart for
maximum load per dimmer.
remove all
inner side
sections
Bend back
and forth to
remove side
section
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
cut
(if necessary)
5/8"
(1.6 cm)
strip Gage (measure
bare wire here)
Preparing and connecting wires:
Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are
straight (cut if
necessary)
. Remove insulation from each wire in the wall
box as shown:
• For single-Pole application, go to step 4a.
• For 3-Way coordinating remote (no LEDs) application, go to step 4b.
• For 3-Way Matching remote (with LEDs) application, go to step 4c.
Dimmer
Insulating
Label
Black
Primary
Side
Electronic
Low-Voltage
Transformer
Hot (Black)
Black
Line
120VAC, 60Hz
Neutral (White)
Red
Yellow/Red
White
White
Green
Ground
WIrInG DIMMEr:
connect wires per WIrInG DIaGraM as follows:
• Green or bare copper wire in wall box to Green dimmer lead.
• Line Hot wall box wire to Black dimmer lead.
• Load wall box wire to Red dimmer lead.
• Line Neutral wall box wire to White dimmer lead.
• Yellow/Red wire should have Red insulation label affixed.
notE:
If insulating label is not affixed to Yellow/Red dimmer lead,
use electrical tape to cover.
•
Proceed to step 5.
Hot (Black)
Neutral (White)
Dimmer
Coordinating Remote (no LEDs)
YL/RD
Yellow/Red
RD
White
Red
Black
Black
BK
WH
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Electronic
Low-Voltage
Transformer
Primary
Side
(unused)
(unused)
WIrInG DIMMEr:
connect wires per WIrInG DIaGraM as follows:
notE:
The dimmer must be installed in a wall box that has a Line
Hot connection.
notE:
Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green dimmer lead.
• Line Hot (common) wall box wire identified (tagged) when
removing old switch to Black dimmer lead.
• First Traveler wall box wire to Red dimmer lead
(note wire color)
.
• Remove Red insulating label from Yellow/Red dimmer lead.
• Second Traveler wall box wire to Yellow/Red dimmer lead
(note
wire color)
. This traveler from the dimmer must go to the terminal
screw on the remote marked "YL/RD".
• Line Neutral wall box wire to White dimmer lead.
WIrInG coorDInatInG rEMotE:
connect wires per WIrInG DIaGraM as follows:
notE:
"BK" and "RD" terminals on coordinating remote are unused.
Tighten both screws.
notE:
Maximum wire length from dimmer to last remote is
300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch
to First Traveler
(note color as above)
.
• Second Traveler wall box wire
(note color as above)
to terminal
screw marked "YL/RD". This traveler from the remote must go to
the Yellow/Red dimmer lead.
• Remove White insulating label from terminal screw marked "WH".
• Line Neutral wall box wire to terminal screw marked "WH".
•
Proceed to step 5.
InstaLLInG Your DIMMEr
notE:
Use check boxes when Steps are completed.
2
4
3
1
2
4
1
5
3
single Pole
1.
Line (Hot)
2.
Neutral
3.
Ground
4.
Load
3-Way
1.
Line or Load
(see important instruction below)
2.
Neutral
3.
Ground
4.
First Traveler – note color
5.
Second Traveler – note color.
notE:
For
matching remote w/LEDs installation, the
First traveler
becomes Line Hot.
MuLtI-DEVIcE aPPLIcatIon
In multi-device installations, the side sections of the mounting straps
may require removal. Use pliers to carefully bend side sections back
and forth until they break off.
If installing Dimmer in a single device application, proceed with the
InstaLLInG Your DIMMEr
section. If installing Dimmer in a
multi-device application, proceed as follows:
Installing Dimmer by itself or with other devices:
changing the color of your Dimmer:
Your Dimmer includes three color options. The Dimmer ships with the
White frame attached. To change color of frame, proceed as follows:
Push in side at
tab to release
Line up tabs and
press in side to attach
WarnInG:
to aVoID FIrE sHocK or DEatH; turn
oFF PoWEr
at circuit breaker or fuse and test that power
is off before wiring!
step 1
Identifying your wiring application
(most common):
notE:
If the wiring in your wall box does not resemble any
of these configurations, consult a qualified electrician.
step 2
step 3
single Pole Wiring application:
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove
this insulating label.
1
4
Black
White
Green
Red
Yellow/Red
2
3
step 4a
step 4a cont'd
Coordinating Remote
Dimmer
BK
WH
YL/RD RD
5
1
4
5
Green
Yellow/
Red
Red
Black
White
2
1
4
3
2
3
3-Way Wiring with coordinating Dimming or
switching remote (no LEDs) application:
(coordinating Dimming remote depicted)
step 4b
step 4b cont'd