background image

WARNINGS AND CAUTIONS

:

•  ON/OFF LED for remote load control.
•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult a qualified electrician.
•  Vizia™ RF RZCZ4 remote does not control the load, but provides scene applications to operate with Vizia

TM

 RF switches.

•  Recommended minimum wall box depth is 2-1/2".

WARNINGS AND CAUTIONS

:

•  Can call up four (4) zone ON/OFF with advanced Programmer/Remote (see RZCPG).
•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.

4-Zone Controller

Cat. No. RZCZ4

120VAC, 60Hz

INSTAllATION INSTRUCTIONS

DI-000-RZCZ4-00A-X1

 Tools needed to install your 4-Zone Controller:

Slotted/Phillips Screwdriver 

Electrical Tape 

Pliers 

 

Pencil 

 

 

Cutters 

 

Ruler

Changing the color of your 4-Zone Controller:

Your 4-Zone controller includes three color options. The controller ships 

with the White frame attached. To change color of frame, proceed as 

follows:

line up tabs 

and press in 

side to attach

Push in 

side at tab 

to release

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

WARNING: 

TO AVOID FIRE, SHOCK OR DEATH; TURN 

OFF POWER 

at circuit breaker or fuse and test that power is off 

before wiring!

 

Step 1

Compatible with

enabled products!

TM

 

Step 3

Preparing and connecting wires:

This 4-Zone controller can be wired using side wire terminal 

screws or through backwire openings. Choose appropriate wire 

stripping specifications accordingly.

•  Make sure that the ends of the wires from the wall box are 

straight (cut if necessary).

Side Wire Connection 

Side wire terminals accept 

#14 AWG 

solid wire copper only

.

5/8" 

(1.6 cm)

Strip Gage 

(measure bare 

wire here)

Cut 

(if necessary)

Back Wire (either hole may be used) 

Back wire openings use #14-12 AWG 

solid wire copper only

Programmer/Remote 

Cat. No. RZCPG

ON

ON

ON

ON

OFF

OFF

OFF

OFF

Menu 

Button

Center 

Button

WIRING SWITCH:

Connect wires per WIRING DIAGRAM as follows:

•  Green or bare copper wire in wall box to Green terminal screw.

•  Line Hot wall box wire to terminal screw marked "BK".

•  Line Neutral wall box wire to terminal screw marked "WH".

Hot (Black)

Neutral (White)

Line

120VAC, 60Hz

BK

WH

Green

Ground

4-Zone Controlller

Wiring Application:

 

Step 4

Identifying your wiring application (most common):

NOTE:

 If the wiring in your wall box does not resemble this 

configuration, consult a qualified electrician.

 

Step 2

 INTRODUCTION

Leviton’s Vizia

TM

 RF components are designed to communicate with 

each other via Radio Frequency (RF) to provide remote control of your 

lighting. Using RF technology allows Leviton to provide the greatest 

signal integrity possible. Each module in Leviton’s Vizia

TM

 RF component 

line is a Z-Wave

TM

 enabled device. In a Z-Wave

TM

 network, each device 

is designed to act as a router. These routers will re-transmit the RF signal 

from one device to another until the intended device is reached. This 

ensures that the signal is received by its intended device by routing the 

signal around obstacles and radio dead spots. The 4-Zone Controller 

is compatible with any Z-Wave™ enabled network, regardless of the 

manufacturer and can also be used with other devices displaying the 

Z-Wave™ logo.

•   This is a Z-Wave™ Controller
•   Zone/Area control without traveler wires
•   Can control ON/OFF dim/bright for up to 4 Zones/Area.
•   ON/OFF LED
•   Two way communication
•   RF reliability
•   Ease of installation – No new wiring
•   Compatible with other Z-Wave™ enabled devices

 FEATURES

 

Step 6

Including 4-Zone Controller into Z-Wave

TM

 

Network:

NOTES:

• 

If using a non-Leviton Programmer/Remote, refer to the Programmer/

Remote instruction sheet.

• 

4-Zone controllers incuded into a Z-Wave

TM

 network must be updated 

after you have included all other devices.

A)

  If using a Leviton Z-Wave

TM

 Programmer/Remote, Cat. No. RZCPG, 

press the Menu button and scroll down to System Setup. Press the 

center button to select System Setup Menu. Press the center button to 

select Network. Press the center button to <Include Node>.

 

Step 6 cont'd

B)

  If using RZCPG Programmer/Remote, you will be prompted to place 

4-Zone controller into programming mode.

C)

  To access Program mode, press and hold the 

left side of buttons 1 and 3 

(refer to figure)

Wait 5 seconds until the LED turns Amber. 

Release the button and the LED will blink 

Amber. You are now in Programming mode.

 

NOTE:

 If the LED on the 4-Zone controller 

turns solid Red while including, there has 

been a communication error.

D)

  While standing close to the 4-Zone controller 

(approximately 2-5 ft.), press the center button 

on the Programmer/Remote to <Include> 

device in the network. 

NOTE:

 Only one device 

may be included at any time.

E)

  The Primary Programmer/Remote will assign 

a Home ID, Node ID, and Name for this 

device.

 

NOTE:

 This information will be stored in the Programmer/Remote to 

be used for future reference.

 

NOTE:

 You may name or edit the node of this device at this time.

F)

 

The 4-Zone controller is now installed in the network

.

G)

  After all devices are included into the network, the controller must 

be updated to allow proper network function. To update controller 

proceed as follows:

 

•   If using a non-Leviton Programmer/Remote, refer to the 

Programmer/Remote instruction sheet for updating controller.

 

•   If using Leviton Z-Wave

TM

 Programmer/Remote, Cat. No. RZCPG, 

press the Menu button and scroll down to System Setup. Press 

the center button to select System Setup Menu. Press the center 

button to select Network. Press the center button to select Update 

"cntrl". When prompted, press desired button on 4-Zone controller.

 

•   Wait until the RZCPG Programmer/Remote confirms completion. 

Update is done.

NOTE:

 If the 4-Zone controller has been 

successfully Included in the network and 

the user tries to Include it again without first 

excluding it from the network, the controller 

will retain the first node ID it had received and 

ignore the second.

After frame is removed, remove existing push buttons by pressing out 

buttons from back of frame and replace them with desired color change 

push buttons by pressing in from front of frame. To make IR capable, use 

new DIM/BRIGHT button with IR window.

INSTAllING YOUR 4-ZONE CONTROllER

NOTE:

 Use check boxes           when Steps are completed.

•  Restore power at circuit breaker or fuse. 

•  LED should turn ON, when any button is pressed. 

If lED does not turn 

ON, refer to the TROUBlESHOOTING section.

•  Position all wires to provide room in 

outlet wall box for device.

•  Ensure that the word “TOP” is facing up 

on device strap.

•  Partially screw in mounting screws in 

wall box mounting holes.

 

NOTE:

 Dress wires with a bend as 

shown in diagram in order to relieve 

stress when mounting device.

Testing your 4-Zone Controller prior to mounting 

in wall box:

 

Step 5

1.

  Line (Hot)

2.

  Neutral

3.

  Ground

Reviews: