FEATURES

• Leviton's Decora

® 

style design

• Color conversion available

• Minimum Brightness Adjustment

• ON/OFF indicates status of load

INSTALLATION INSTRUCTIONS

WARNING:

 TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND

REGULATIONS.

WARNING:

 IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED

ELECTRICIAN.

WARNING:

 TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT

INSTALL TO CONTROL A RECEPTACLE, FLUORESCENT LIGHTING, A MOTOR- OR A TRANSFORMER-OPERATED
APPLIANCE OTHER THAN APPROPRIATE LOW-VOLTAGE LIGHTING.

CAUTION (For Incandescent Only):

 USE WITH INCANDESCENT OR 120V HALOGEN FIXTURES ONLY.

CAUTION (For Magnetic Low-Voltage Only):

1. USE WITH MAGNETIC LOW-VOLTAGE TRANSFORMERS, INCANDESCENT, OR 120V HALOGEN FIXTURES ONLY. USE

A LEVITON ELECTRONIC LOW-VOLTAGE DIMMER TO CONTROL ELECTRONIC (SOLID STATE) LOW-VOLTAGE
TRANSFORMERS.

2. WHEN A MAGNETIC LOW-VOLTAGE CIRCUIT IS OPERATED AT A DIM LEVEL, WITH ALL LAMPS INOPERATIVE,

EXCESS CURRENT MAY FLOW THROUGH THE TRANSFORMER. TO AVOID POSSIBLE TRANSFORMER FAILURE DUE
TO OVERCURRENT, USE A TRANSFORMER THAT INCORPORATES THERMAL PROTECTION OR A FUSE AT THE
PRIMARY WINDINGS.

OTHER CAUTIONS:

1. DISCONNECT POWER WHEN SERVICING OR CHANGING LAMPS.

2. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES

MARKED CO/ALR OR CU/AL.

MULTI-GANG INSTALLATION:

When ganging dimmers, the side sections of the mounting strap
must be removed. Use pliers to carefully bend side sections back
and forth until they break off (see Figure 1). The side sections
dissipate heat, so removing them requires a derating of the
dimmer's capacity (see chart).

MAXIMUM BULB WATTAGE (For Magnetic Low-Voltage Only):

Low-voltage dimmers are rated in Volt-Amps (VA). The maximum
bulb wattage is determined by the efficiency of the transformer in
the low-voltage lighting system. Transformer efficiencies will vary
from different manufacturers; consider 75% efficient as average.
Use the chart to determine maximum bulb wattage for typical
transformer efficiency ratings.

TO INSTALL:

1.

WARNING:

 TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF

POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT
POWER IS OFF BEFORE WIRING!

2. Remove existing wallplate and switch, if applicable.

3. Remove 3/4¨ (1.9 cm) of insulation from each circuit conductor.

Make sure the ends of wires are straight.

4. Connect lead wires per WIRING DIAGRAM as follows:

WARNING:

 CONNECT A MAGNETIC LOW-VOLTAGE DIMMER

ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A
MAGNETIC LOW-VOLTAGE TRANSFORMER. 
Twist strands of
each lead tightly and, with circuit conductors push firmly into
appropriate wire connector. Screw connectors on clockwise
making sure that no bare conductor shows below the wire
connectors. Secure each connector with electrical tape.

NOTE: This model incorporates a trim adjustment which will
allow the installer to precisely set the low end of the dimming
range to suit each installation. This adjustment is preset at the
factory and should require no further adjustments for most
installations. If adjustment is required proceed as follows,
otherwise continue with step 8:

5. Restore power at circuit breaker or fuse. Raise and lower (full

bottom stroke) the slider several times (see Figure 1). The
GREEN LED will turn ON and OFF indicating power to the
switch. Set the slider to the ON position (GREEN LED OFF).
Position the slider to the minimum brightness level (bottom of
stroke, before it clicks OFF).

6. The brightness adjustment is located at the top of the dimmer

back cover (see Figure 1). Using a small, insulated screwdriver,
rotate the trim adjustment until the desired level of minimum
brightness is obtained.

R

PK-92931-10-00-0A

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for
the benefit of anyone else that this product at the time of its sale
by Leviton is free of defects in materials and workmanship under
normal and proper use for two years from the purchase date.
Leviton’s only obligation is to correct such defects by repair or
replacement, at its option, if within such two year period the
product is returned prepaid, with proof of purchase date, and a
description of the problem to Leviton Manufacturing Co., Inc.,
Att: Quality Assurance Department, 59-25 Little Neck
Parkway, Little Neck, New York 11362-2591 (In Canada send
to Leviton Mfg. of Canada Ltd., 165 Hymus Blvd., Point Claire,
(Quebec), Canada H9R 1E9).
 This warranty excludes and there
is disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels
or instructions. There are no other or implied warranties of any
kind, including merchantability and fitness for a particular purpose,
but if any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to
two years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage to,
or loss of use of, any equipment, lost sales or profits or delay or
failure to perform this warranty obligation. The remedies provided
herein are the exclusive remedies under this warranty, whether
based on contract, tort or otherwise.

For Technical Assistance Call:

1-800-824-3005 (U.S.A. Only)

1 800 405-5320 (Canada Only)

www.leviton.com

PK-92931-10-00-0A

          Single Pole

120VAC, 60Hz

Incandescent

Cat. No. INI06-10, 600W

Cat. No. INI06-1L, 600W (Lighted)

                    Cat. No. INI10-1L, 1000W (Lighted)

                           Magnetic Low-Voltage

       Cat. No. INM06-1L, 600VA (Lighted)

Cat. No. INM10-1L, 1000VA (Lighted)

INSTALLATION INSTRUCTIONS

More than

 Cat. No.

 Single

 Two Gang

  2 Gang

 INI06-10

  600W

    500W

400W

 INI06-1L

  600W

    500W

 400W

 INI10-1L

  1000W

    800W

700W

 INM06-1L

   600VA

    500VA

400VA

 INM10-1L

  1000VA

    800VA

 700VA

MAXIMUM LOAD PER DIMMER FOR MULTI-GANG

R

           

 Two

  More than

            Rating               Single      Gang

  

  2 Gang

            600VA                450W

 375W

  300W

1000VA               750W

 600W

  525W

MAXIMUM BULB WATTAGE AT 75% EFFICIENCY

/

/

/

/

/

/

/

/

/

/

C O L L E C T I O N  B Y  L E V I T O N

Cat. Nos.

INI06-1L
INI10-1L

INM06-1L
INM10-1L

/

/

/

/

Figure 1 - Dimmer Functions

Slider

ON/OFF

LED

(Lighted Version ONLY)

Trim Adjustment 

Screw

Mounting Strap

Side Sections