FEATURES
• Intellisense Circuitry
•
Works with Transmitters (hand-held) and Controllers
• ON/OFF LED indicates status of load
•
DHC Scene Capable
• Manual ON/OFF capability at load
•
One Button Programming
• 2-Way communication when used with 2-Way transmitters
INTRODUCTION
Leviton Residential Powerline Carrier Components are designed to provide the greatest signal integrity and noise immunity possible. However, in some environments
intense electrical noise can cause interference with the signal. Leviton has developed hardware and techniques for overcoming this interference when properly applied.
LEVITON’S DHC DEVICES FEATURE INTELLISENSE, THE RIGHT TYPE OF AUTOMATIC GAIN CONTROL (AGC)
Leviton DHC devices use Intellisense, a special gated-type of AGC, to help eliminate noise problems. This circuit
feature is ideal for powerline carrier systems because it only operates during the signal window when receivers
listen for command signals. Noise levels in the signal window are never as high as they are during other portions
of the AC power curve. Therefore, Leviton’s Intellisense gated AGC will desensitize a receiver to noise signals
with only a minimal reduction in command signal sensitivity. The result: Problems from noise interference are
dramatically reduced without affecting overall system performance.
It is the responsibility of the specifier/installer to test for signal strength and the presence of noise using Leviton
test equipment, Cat. Nos. 6385 (Signal Test Transmitter) and 6386 (Signal Strength Indicator), and to properly
apply signal coupling and noise reduction equipment according to the guidelines provided in the Decora Home
Controls (DHC) Technical Manual and the DHC Troubleshooting Guide.
Leviton specifically denies any warranty of performance, stated or implied, where electrical noise interference
exists at the time of installation, or subsequent to installation by the addition of noise-producing devices or
equipment, or where these components have been installed for non-residential applications.
DHC Components are for residential use only. Installation for any other application voids any warranty, stated or implied.
DESCRIPTION
The Leviton Plug-In Radio Frequency (RF) Module, Cat. No. HCPRF, is designed for use with DHC Residential Powerline Carrier Components. Cat. No. HCPRF functions
as a remote control receiver which accepts ON/OFF, DIM, BRIGHT, and ALL LIGHTS ON/OFF commands of up to 256 DHC codes from DHC remote controls
(refer to
Figure 1)
.
The device re-transmits the signal throughout existing house wiring to control both hard wired and plug-in dimmers and switch modules. The HCPRF contains an integral
receptacle which can be remotely or locally turned ON or OFF
(refer to Figure 3)
; it is suitable for incandescent lamp loads up to 300W . It can also be programmed to
respond to scene commands from scene controllers. The device can be used with or without a load attached locally.
APPLICATIONS
DHC devices will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID
lighting). This includes mercury-vapor, sodium vapor and metal halide lamps.
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF an ON, the
user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and the receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/tv technician for help.
INSTALLATION INSTRUCTIONS
WARNING:
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
WARNING:
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
WARNING:
TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A MOTOR-OPERATED
APPLIANCE, FLUORESCENT LIGHTING FIXTURE, OR A TRANSFORMER-SUPPLIED APPLIANCE.
CAUTION:
UNPLUG UNIT WHEN SERVICING FIXTURE OR CHANGING BULBS.
CAUTION:
SAVE THIS INSTRUCTION SHEET. IT CONTAINS IMPORTANT TECHNICAL DATA ALONG WITH TESTING AND TROUBLESHOOTING INFORMATION
WHICH WILL BE USEFUL AFTER INSTALLATION IS COMPLETE.
TO INSTALL:
NOTE:
The Cat. No. HCPRF may be used with or without a load connected to its integral receptacle. If desired, connect lamp load as follows:
1.
Carefully unwind and straighten out Antenna attached. For best reception and range, ensure that Antenna is orientated straight up.
2.
Locate lamp to be controlled by Plug-In Control Module and ensure it is operational. Turn lamp OFF and unplug lamp cord from wall outlet.
3.
Attach lamp plug into Module receptacle noting proper polarity of blades.
4.
Plug Module into wall receptacle. Turn lamp ON and verify that receptacle is live by pressing the button on the front of the Module. The lamp should turn ON. Please
note that if receptacle is controlled by a wall switch, the switch must be kept ON at all times. After verifying, press button on Module to turn lamp OFF.
DI-000-HCPRF-00A
Plug-In RF Controller
Rated: 120VAC, 60Hz
Cat. No. HCPRF
Incandescent: 300W max., 60W min.
INSTALLATION INSTRUCTIONS
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and
not for the benefit of anyone else that this product at the
time of its sale by Leviton is free of defects in materials and
workmanship under normal and proper use for two years
from the purchase date. Leviton’s only obligation is to correct
such defects by repair or replacement, at its option, if within
such two year period the product is returned prepaid, with
proof of purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
York 11362-2591 (In Canada send to Leviton Mfg. of
Canada Ltd., 165 Hymus Blvd., Point Claire, (Quebec),
Canada H9R 1E9).
This warranty excludes and there is
disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in
accordance with any labels or instructions. There are no
other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if
any implied warranty is required by the applicable jurisdiction,
the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited
to two years. Leviton is not liable for incidental, indirect,
special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost
sales or profits or delay or failure to perform this warranty
obligation. The remedies provided herein are the exclusive
remedies under this warranty, whether based on contract,
tort or otherwise.
Command Signal
is picked up
Gated AGC ignores
High noise levels
outside signal window
Noise is not
picked up
Signal Window
Signal Window
Receiver sensitivity
with Intellisense
gated AGC
DI-000-HCPRF-00A
DI-000-HCPRF-00A
10/10/02, 3:18 PM
1