Single Pole Humidity Sensor and Fan Controller

Cat. Nos. IPHS5 - INDOOR USE ONLY

120VAC, 60Hz - Single Pole Only 

Incandescent: 600W - MLV/Fluorescent: 400VA - LED/CFL: 150W - Fan: 1/6Hp

INSTALLATION

ENGLISH

DI-000-IPHS5-02B

DI-000-IPHS5-02B

WARNINGS
•  TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER 

OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!

•  TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to 

control a receptacle, or a load in excess of the specified rating.  

•  To be installed and/or used in accordance with electrical codes and regulations.
•  If you are not sure about any part of these instructions, consult an electrician.

CAUTIONS
•  Clean outer surface gently with damp cloth only.  

DO NOT use soaps or cleaning 

liquids.

•  No user serviceable components.  

DO NOT attempt to service or repair.

•  Use this device 

WITH COPPER CLAD WIRE ONLY.

Installation

WARNING: TO AVOID FIRE, SHOCK OR DEATH, 

turn off power at circuit breaker or fuse and test that 

the power is off before wiring. 

1.   Identify your wires  

(most common):

NOTE: If the wiring in the wall box does not 

resemble this configuration, consult an electrician.

2.  Wire.

  

Working on one connection at a 

time, connect wires as shown.

 

 NOTE:  Neutral connection  

is required.

GR

OUND

GROUND

NE

UTRAL

NE

UTRAL

LINE

LO

AD

3.  Test.

Restore power. Locator light 

will illuminate but will not blink.

Refer to Locator Light status 

chart to determine  

operational status.

Operation

 

1.   Manual  

(for all modes of operation)

•  Press push pad to manually turn on the load.  

Internal time will activate and turn off load 

when set time out expires.

•  Press and release push pad to manually turn 

off load.

4.  Mount.

Turn off power at circuit breaker before 

completing the outlet installation.

 

•   Gently push wires into wall box.  Screw 

outlet to box.

 

•   Install wallplate base and snap on 

Decora

®

 wallplate.

 

•  Restore power.

You Will Need:

•  Slotted/Phillips screwdriver
•  Pencil
•  Electrical tape
•  Cutters
•  Pliers 
•  Ruler

Location

Features

The humidity sensor and fan controller senses the humidity of your bathroom 

and turns your bath fan or fan/light on when the humidity gets too high, 

reducing condensation in your bathroom and increasing ventilation when used 

in other household spaces.

  •   Compatible with Incandescent, LED, CFL and Fluorescent loads when 

used with combination fan and light fixtures.

  •  Sensitivity adjustment.

  •  Built in countdown timer feature for manual operation.

  •   Automatic ventilation/air circulate mode for continuous operation with 

hourly preset time outs.

Changing your device color

Remove

Replace

2.  To adjust settings

•  Remove wallplate and sensor face  

(see section "Changing Your Device Cover".)

•  Adjust dials with small screwdriver.

NOTE: DO NOT 

rotate the adjustment 

dials past the stop 

marks shown.

Locator Light Status Chart

Locator light action

Status

ON

Fan OFF

OFF

Fan ON

Blinking 2 seconds ON, 2 seconds OFF

Air Cycle Mode is active

Blinking 2 seconds ON, 1/10 second OFF

Manual override

Fast blink

Defective unit

LIN

E

LO

AD

NE

UTRA

L

GR

OUND

3.  Dial Descriptions

Time 

1.   Adjust the time selector to set the time out duration, which is the minimum 

desired length of time the fan will remain ON after being turned on in any 

mode of operation.

2.   For use with all Automatic Modes of Operation.

Sensitivity - To reduce false activation, reduce sensitivity.

1.   Hi - use for large rooms
2.   Medium - use for medium sized rooms
3.   Low 
- use for small rooms
4.   OFF - used in Air Cycle mode.

Humidistat

1.   OFF - device ignores the humidity set point and controls fan based on 

detection of excess humidity.

2.   Minimum relative humidity - when the humidity is below your set level, the 

fan can only be turned on manually.

4.  Default Settings

•   For bathroom applications the device should be placed 

at a level to detect steam. Placing the detector directly 

above a heater or near drafts is not recommended.

•   NOTE: DO NOT use to control a fan/light combination 

where the fan/light is the only means of illumination.

•   NOTE: The Leviton humidity sensor and fan control will 

not eliminate condensation and must be used 