![Levitaz Hydrofoil R5 Manual Download Page 22](http://html.mh-extra.com/html/levitaz/hydrofoil-r5/hydrofoil-r5_manual_1885591022.webp)
MAINTENANCE AND REPAIR INFORMATION
GDM003450-ENG-A
Manufacturer: LEVITA
Z
21 / 25
Contact:
Confidentiality code: GREEN
9
MAINTENANCE AND REPAIR INFORMATION
9.1
Maintenance
Clean all hydrofoil parts with fresh water after every use and dry the parts.
To prevent oxidation of the screws and threads, we strongly recommend that
before reassembling use re-greased screws (as per the assembly instructions).
Check your hydrofoil prior to each use. Ensure that the screws are tight and there
are no cracks, holes or scratches which could compromise your Foil System’s
structure.
Do not overtighten screws as they are subject to extreme loads. Screw tightness
should be checked regularly.
Always store the disassembled product in suitable covers and a durable carrier
bag for optimal protection. This is to prevent unnecessary sun exposure,
exposure to hot temperatures, scratches and other wear and tear.
NOTICE!
Failure to do so may cause serious damage to the product and
void the warranty.
9.2
Repair information
INSPECTED CONDITION
CORRECTIVE MEASURE
Visible fiber failure or any other
heavy damage like delamination
(separation of the single layers of
the composite).
DO NOT REPAIR
the reinforced plastic components!
Dismantle the product and send it back to Levitaz.
It is not clear if the damage is
critical or not.
Take a photo, document the extent of the damage
and contact Levitaz for advice.
If any other damage or wear to the product is identified but not described in this table,
contact Levitaz to identify the appropriate corrective measure. See www.levitaz.com
Dispose of worn parts as instructed in the chapter “Disposing of used parts”.