background image

 

                                                               

 

I

 

 

 

 

 

MSL-3S79 

3-Slot Gigabit Modular L2 Managed Switch 

 

 

 

User Manual 

 

 

 

 

 

V1.0 

Summary of Contents for MSL-3S79

Page 1: ...I MSL 3S79 3 Slot Gigabit Modular L2 Managed Switch User Manual V1 0...

Page 2: ...in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to tr...

Page 3: ...3 18B4 2 Segment Application 13 4BChapter 5 Console Management 15 19B5 1 Connecting to the Console Port 15 20B5 2 Login in the Console Interface 15 21B5 3 CLI Management 16 5BChapter 6 Web Based Manag...

Page 4: ...B6 5 4 2 Trunk Information 31 86B6 5 4 3 Port Activity 31 62B6 5 5 Port Mirror 32 63B6 5 6 Rate Limiting 34 27B6 6 Protocol 34 64B6 6 1 VLAN 34 87B6 6 1 1 VLAN Mode Configuration 35 88B6 6 1 2 Port VL...

Page 5: ...105B6 7 2 3 MAC Address Table Aging 53 73B6 7 3 IP Security 53 74B6 7 4 ACL 54 29B6 8 Factory Default 55 30B6 9 Save Configuration 55 31B6 10 System Reboot 56 6BTroubleshooting 57 7BAppendix A Comman...

Page 6: ...VI 46BDHCP Server Commands Set 77 47BSecurity IP Commands Set 78 48B802 1X Commands Set 78 49BLLDP Commands Set 79 50BACL Commands Set 80...

Page 7: ...ss in an 16K entry MAC address table MDI Medium Dependent Interface Port is also called an uplink port The MDI port does not cross transmit and receive lines which is done by the regular ports MDI X p...

Page 8: ...LED Indicators System Power 10 100 1000TX module Link Activity 1000 100 10Mbps speed 8 Port Gigabit Fiber module Link Activity 8 Port MINI GBIC Link Activity 4 Port Gigabit copper 4 Port MINI GBIC mod...

Page 9: ...MAC Address 16K Storage Temp 40 70 5 95 RH Operational Temp 0 45 5 95 RH Power Supply AC 100 240V 50 60Hz Redundant Power DC 12 48V Power Consumption 35 Watts Ventilation 2 fan at the rear EMI Compli...

Page 10: ...p MIB RFC 1757 RMON MIB Private MIB SNMP Trap Cold start Warm start trap Link down Link up trap Authentication fail trap Firmware Upgrade TFTP Configuration upload and download System quick installati...

Page 11: ...vice Port based Tag based IPv4 Type of service IPv4 Different service IGMP IGMP v1 v2 Supports 256 multicast groups and IGMP query Port Security Support 128 entries of MAC address for static MAC and a...

Page 12: ...b Telnet SNMP interface SNTP Support RFC 2030 SNTP client SMTP System supports 5 mail accounts and 2 Mail servers for Primary and Secondary The SMTP will auto send event message to supervisor whom is...

Page 13: ...r Cord Rack mounted kit RS 232 Cable CD Manual Compare the contents of your MSL 3S79 package with the standard checklist above IF any item is missing or damaged please contact your local dealer for se...

Page 14: ...cators gives real time information of systematic operation status The LED indicators are located in every module The LED indicators will be different for different module The following table provides...

Page 15: ...abit Copper 1000 100 Green Link on 1000Mbps mode Amber Link on 100Mbps speed mode Off Link on 10Mbps speed mode or No device attached LK ACT Green Ethernet Link is connected Blink The port is receivin...

Page 16: ...or transmitting data Off No device attached or Link is disconnected 13B2 3 Rear Panel The 3 pronged power plug is located at the Rear Panel of the MSL 3S79 as shown in figure The Switches will work w...

Page 17: ...stallation The switch come with a rack mounted kid and can be mounted in an EIA standard size 19 inch Rack The Switch can be placed in a wiring closet with other equipment Perform the following steps...

Page 18: ...outlet The internal power can work with AC in the voltage range of 100 240VAC frequency 50 60Hz or 12 48VDC It s optional Besides The AC and DC input can be used for redundant power supply When one f...

Page 19: ...mall switched workgroups to form a larger switched network Meanwhile you can also use Ethernet or Gigabit fiber ports to connect switches 17B4 1 Desktop Application The MSL 3S79 is designed to be a sw...

Page 20: ...bsequently used to filter and forward all traffic based on the destination address You can use any of the RJ 45 port of the MSL 3S79 to connect with another Switch or Hub to interconnect each of your...

Page 21: ...connector to connect a terminal or PC to the Console port Connecting the switch to a terminal via RS 232 cable 20B5 2 Login in the Console Interface When the connection between Switch and PC is ready...

Page 22: ...n shows up press Enter key to get into command line mode Please see below figure for login screen 21B5 3 CLI Management The system supports console management CLI command After you login to the system...

Page 23: ...lets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen NOTE By default IE5 0 or later version does not allow Java Applets to activate sockets In fact t...

Page 24: ...ion System Name Assign the name of switch The maximum length is 31 bytes Description Display the description of switch The maximum length is 31 bytes Location Assign the switch physical location The m...

Page 25: ...Status display the status of Fan 1 Fan 2 Status display the status of Fan 2 76B 6 4 2 2 Management Software Firmware Version display the firmware version Configure Data version display the configure d...

Page 26: ...in this column for the switch The default IP is 192 168 1 1 Subnet Mask Assign the subnet mask of the IP address If IP Address Mode function is in DHCP mode user need not assign the subnet mask manua...

Page 27: ...starting IP address and how many IP addresses within this address pool For instance user can set 192 168 1 100 to be the beginning IP address and 50 can t be greater than 253 to be the maximum number...

Page 28: ...you have your TFTP server ready and the firmware image is on the TFTP server 1 TFTP Server IP Address Fill in your TFTP server IP 2 Firmware File Name The name of firmware image 3 Click Apply TFTP Up...

Page 29: ...orrect restore file name 3 Click Apply TFTP Configuration Restore interface 56B 6 4 6 System Event Log 80B 6 4 6 1 LOG Configuration You can mark the check box of Local Logging Remote Logging and SMTP...

Page 30: ...Facility Level Trap Level Log Server IP 1 and Log Server IP 2 Facility Level Set the level range of 16 to 23 Trap Level Set the level range of 0 to 7 Log Server IP 1 Assign a remote log server IP addr...

Page 31: ...Level User can select the system log events and SMTP events When selected events occur the system will send out the log information The range of Logging Event Level is from level 0 to level 7 When th...

Page 32: ...ystem will issue the logs Cold Start Event when the device executes cold start action the system will issue a log event Warm Start Event when the device executes warm start the system will issue a log...

Page 33: ...ent to Flash ROM Logging ROM Table interface 57B 6 4 7 Security Manager Change login user name and password for the management security issue User Name Key in the new user name The default is admin Ne...

Page 34: ...26B6 5 Port 58B 6 5 1 Port Statistics Display the port statistic information Port Statistic interface 59B 6 5 2 Port Information The following information provides the current port statistic informati...

Page 35: ...set to disable or enable mode If the port setting is disabled it will not receive or transmit any packet 3 Auto Negotiation enable or disable auto negotiation 4 Speed when Auto Negotiation is disable...

Page 36: ...hat Link Aggregation Group and enable its transmission and reception functions in an orderly manner Link aggregation lets you group up to eight ports into two dedicated connections This feature can ex...

Page 37: ...oup Id and click Delete button Trunk Configuration interface 85B 6 5 4 2 Trunk Information After setting up the trunk group user will see the related information as below Trunk Information interface 8...

Page 38: ...6 5 5 Port Mirror The port mirror is a method for monitor traffic in switched networks Traffic through ports can be monitored by specific port That means traffic goes in or out monitored ports will be...

Page 39: ...rt for analyzing all monitor port traffic User can connect mirror port to LAN analyzer or Netxray 3 Monitor Port The ports which user wants to monitor All monitored port traffic will be copied to anal...

Page 40: ...s Type in the output rate limit which is a multiple of 312 Port Configuration interface 27B6 6 Protocol 64B 6 6 1 VLAN A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain...

Page 41: ...VLAN operation mode is 802 1Q VLAN Mode Configuration interface 88B 6 6 1 2 Port VLAN Id Configuration 1 Port Select the port number in the table list 2 VLAN ID Key in the VLAN ID 3 Ingress Filter En...

Page 42: ...oup 1 Select the VLAN group in the table list 2 Click Edit VLAN Table Configuration interface 3 User can add remove the ports from a VLAN group 4 Click Next VLAN Table Configuration Edit interface 5 M...

Page 43: ...nected device that is running STP or RSTP protocol 90B 6 6 2 1 STP System Configuration User can view spanning tree information about the Root Bridge User can modify RSTP state After modification clic...

Page 44: ...Enter a value between 1 through 10 Forward Delay Time 4 30 the number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening states to the forwarding stat...

Page 45: ...only be connected to exactly one other bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function...

Page 46: ...ceiving traps or change notices from network devices implementing SNMP SNMP Information Enter the system name contact and location information Name Assign a name for the switch Location Type the locat...

Page 47: ...ring the IP address of the station and a community string To define management stations as trap manager and enter SNMP community strings and selects the SNMP version IP Address enter the IP address of...

Page 48: ...iority Precedence There are 4 priority precedence selections available Click Adpply QoS Configuration interface 93B 6 6 4 2 Port bace Configuration Port Select the number port from the column list Def...

Page 49: ...des 0 63 DSCP priority level Each level has 8 types of priority 0 7 7 is the highest priority When the IP packet is received the system will check the DSCP level value in the IP packet that has been r...

Page 50: ...server 2 Switch Current Time Display the current time of the switch 3 SNTP Client Enable or disable SNTP function When it is enabled user can assign the domain name or IP address of SNTP server for ge...

Page 51: ...s Message Description Query A message sent from the querier IGMP router or switch asking for a response from each host belonging to the multicast group Join Group A message sent by a host to the queri...

Page 52: ...Query being sent Read Only Click Apply IGMP Configuration interface 97B 6 6 6 2 IGMP Static Configuration Multicasts are similar to broadcasts they are sent to all end stations on a LAN or VLAN Multi...

Page 53: ...this standard allows stations attached to an IEEE 802 LAN to advertise to other stations attached to the same IEEE 802 LAN the major capabilities provided by the system incorporating that station the...

Page 54: ...t to a wireless access point or wired switch but prevents the client from gaining access to the port until it provides authority like a user name and password that are verified by a separate server 10...

Page 55: ...of time the switch waits for a server response to an authentication request 6 ReAuthMax Set the number of authentication that must time out before authentication fails and the authentication session e...

Page 56: ...he authenticator Accept The specified port will allow the client accessing in any case Reject The specified port rejects the client accessing regardless of whether the authentication passed or not Cli...

Page 57: ...3B 6 7 2 1 Static MAC Address Table User can add a static MAC address it remains in the switch s address table regardless of whether the device is physically connected to the switch This saves the swi...

Page 58: ...filtering table select the MAC address and click Delete 104B 6 7 2 2 Filter MAC Address Table MAC address filtering allows the switch to drop unwanted traffic Traffic is filtered based on the destinat...

Page 59: ...MAC address table aging function Aging Time 20 620 Assign the aging time in second Address Aging interface 73B 6 7 3 IP Security User can assign up to 10 security IP addresses for accessing the switc...

Page 60: ...matches a permit rule or dropped as soon as it matches a deny rule If no rules match for a list of all permit rules the packet is dropped and if no rules matches for a list of all deny rules the packe...

Page 61: ...on except reserved IP user name and password Factory Default interface 30B6 9 Save Configuration Save all configurations that user has made in the system To ensure the all configuration will be saved...

Page 62: ...56 31B6 10 System Reboot Reboot the switch in software reset Click Reboot to reboot the system System Reboot interface...

Page 63: ...ct the problem try a different cable Non standard cables Non standard and miss wired cables may cause numerous network collisions and other network problem and can seriously impair network performance...

Page 64: ...an be easily monitored through panel indicators which describes common problems you may encounter and where you can find possible solutions to assist in identifying problems If the power indicator is...

Page 65: ...function status save configures Global configuration Enter the configure command while in privileged EXEC mode switch config To exit to privileged EXEC mode enter exit or end Use this mode to configur...

Page 66: ...ration mode Use the ip address interface configuration command to set an IP address for a switch Use the no form of this command to remove an IP address or to disable IP processing switch config ip ad...

Page 67: ...vileged EXEC Use the show fan status command to display fan status switch config show fan status 34BPort Commands Set Commands Command Level Description Default Example interface gigaethernet port ID...

Page 68: ...t input mode bc mc unkuc kno wnuc Interface configuration mode Set rate limit input mode You can enable rate limit for specific packets such as broadcast multicast unknown unicast and known unicast Us...

Page 69: ...no shutdown show interfaces status gigaethernet port channel vlan if num Privileged EXEC Show interface configuration status and configuration switch show interfaces status gigaethernet 1 or switch s...

Page 70: ...ce static witch config interface gigaethernet 1 switch config if mac address t able static hwaddr 000012345678 vlan 1 or witch config interface gigaethernet 1 switch config if no mac address table sta...

Page 71: ...value switch config interface gigaethernet 1 switch config if monitor 3 both or switch config if no monitor 3 or Disable switch config if no monitor all show monitor Privileged EXEC Show port monitor...

Page 72: ...or no qos priority dscp Global configuration mode Set DSCP Map switch config qos priority dscp 61 5 or Default switch config no qos priority dscp qos priority profile profile Global configuration mod...

Page 73: ...the spanning tree priority global configuration command to change the priority Priority must be a multiple of 4096 32768 switch config spanning tree priority 4096 spanning tree max age 6 40seconds Glo...

Page 74: ...st that is used when two switches tie for position as the root switch 128 switch config interface gigaethernet 1 switch config if stp port priority 16 pathcost 200000 stp admin p2p disable enable aut...

Page 75: ...switch vlan vlanmode gvrp show vlan or show vlan GroupName VLAN ID VLAN database mode Show VLAN information switch vlan show vlan or switch vlan show vlan 2 Port Base VLAN mode no vlan group VLAN ID V...

Page 76: ...8021q switchport native vlan PVID or no switchport native vlan Interface configuration mode Set Port PVID 1 switch config interface gigaethernet 1 switch config if switchport native vlan 2 or switch...

Page 77: ...ion Default Example show logging flash ram sendmail trap map Privileged EXEC Show system log information switch show logging flash logging mode local remote smt p or no logging mode local remote smt p...

Page 78: ...config no logging host 192 168 16 5 logging facility value or no logging facility Global configuration mode Set system log facility 23 Switch config logging facility 19 Switch config no logging facili...

Page 79: ...ompany com Switch config no logging sendmail src 0 bill this company com logging sendmail dst 0 dst 1 email addr or no logging sendmail dst 0 dst 1 email addr Global configuration mode Add or delete s...

Page 80: ...system time configuration switch show sntp sntp server ipaddr Global configuration mode Set SNTP server IP address switch config sntp server 192 168 16 5 no sntp server Global configuration mode Set S...

Page 81: ...ration Privileged EXEC Displays the details of an IGMP configuration switch show igmp configuration show mactbl multicast vlan vid Privileged EXEC Shows known multicast addresses for specific VLAN Id...

Page 82: ...interfaces status port channel group id Privileged EXEC Shows trunk information switch show interfaces status port channel 1 show port activity Privileged EXEC Show lacp port activity information acti...

Page 83: ...ver host Host address Global configuration mode Remove the SNMP server host switch config no snmp server host 192 168 1 50 show snmp Privileged EXEC Show snmp configuration switch show snmp 46BDHCP Se...

Page 84: ...onfiguration mode Use the 802 1x misc quiet period global configuration command to specify the quiet period value of the switch 60 switch config 8021x misc quietperiod 10 8021x misc txperiod sec Globa...

Page 85: ...ver IP switch config 8021x system radiusip 192 168 1 1 8021x system serverport port ID Global configuration mode Use the 802 1x system server port global configuration command to change the radius ser...

Page 86: ...ntrol on a port The default action can be Deny or Permit Use the no form of this command to return the port to its default value disable Disable switch config interface gigaethernet 1 switch config if...

Reviews: