Password
If the program has been started for the first time that day, the password has
to be entered. The factory-set password is: ODS 96.
After entering and confirming the following window appears:
Figure 6.4: Parameterization mode, ODS 96 with analog output
In the upper part of the window, information on the connected ODS 96 device
is displayed.
Options
The complete parameter set for the ODS 96 is stored in a default parameter
file. In case of necessary service, the command Options
Write default
parameters can be used to transmit the contents of this file to the ODS 96.
The command Options
Write customer parameters, triggers the same
result as the button Write parameters to ODS.
Working range analog
output
You can adjust which distance corresponds to a voltage of 1 V, 4 mA at the
analog output (lower range limit) and which distance corresponds to a voltage
of 10 V, 20 mA (upper range limit).
The shortest adjustable range is 44 mm for the LED version and 400 mm for
the Laser version.