3.3.3
ODS 96 M/S with Two Switching Outputs
Switching outputs of
the LED and laser
device
Figure 3.6: Behavior of the switching outputs, ODS 96 M/S
ODS 96 M/S with two
switching outputs
The two switching outputs of the ODS 96 M/S are working independently
from each other. Through the teach input, the second signal edge can be
tought at output 1, the first signal edge is situated at the beginning of the mea-
surement range. The first signal edge can be tought at output 2, the second
signal edge is situated at the end of the measurement range.
A teach line is available for both switching outputs, meaning the switching
outputs are tought alternatingly. The presently tought output is displayed
through the simultaneous or alternating flashing of the LEDs.
The outputs can be adjusted independently of each other by using the option-
al programming software.
+U
B
2. switching output
1. switching output
LED: 100 600
Laser: (200) (2000)
Measuring distance
(mm)