Smart Process Gating
Leuze electronic GmbH + Co. KG
MLC 530 SPG
24
4.4
SPG operating modes
Multiple SPG operating modes are available for SPG operation in various applications.
• The operating mode is hardwired via a wire bridge in the connection cable. In the event of a device ex-
change, configuration is neither necessary nor possible.
• The number of the selected operating mode is displayed statically on the 7-segment display of the re-
ceiver.
Tab. 4.3:
Overview of the functions in the individual operating modes
Operating mode
Functions
1
4
5
6
Performance Level
PL d with standard control
PL e with safety control
■
■
■
■
■
■
Minimum time for ending gating (see chapter 4.5.1 "Controlled
gating end")
100 ms
100 ms
100 ms
100 ms
Gating tolerance time t1
4 s
2 s
4 s
4 s
Protective-field filter time
Brief clearing of the protective field (1 s or 2 s) is possible with-
out interruption of the gating event. Small gaps in the load can
thereby be tolerated.
2 s
0.5 s
1 s
2 s
Max. conveyor speed without additional measure
0.1 m/s
0.4 m/s
0.2 m/s
0.1 m/s
Qualified stop
■
■
■
Partial gating
■