Activate or deactivate
ALC function
The
ALC function can be manually deactivated and activated.
Manual deactivation/activation of the
ALC function is always only performed for
the respective active detection process.
The
ALC function remains deactivated for the active detection process until it is
manually reactivated by the operator.
7
Ä
Press the label button until the green ON LED and the yellow OUT LED flash
alternately.
Ä
Release the label button.
NOTICE
The manual deactivation/activation of the
ALC function is stored in
non-volatile memory in the sensor.
Configuration of the easy Teach mode
easy Teach mode of the sensor from intelligent to manual
("easy Teach while the label tape is passing through (dynamic)").
–
Intelligent: The sensor automatically selects the most suitable detection
process.
–
Manual: Manual preselection of the detection process by the operator.
8
Ä
Press the label button until only the green ON LED flashes.
Ä
Release the label button.
The green ON LED continues to flash for 2 seconds and the yellow
CLEAR and PAPER LEDs indicate the changed
easy Teach mode for 2 sec-
onds:
CLEAR LED and PAPER LED ON:
intelligent easy Teach mode active
CLEAR LED and PAPER LED OFF:
manual easy Teach mode active
14
EN