Process data settings (group 6)
The process data setting permits the serial output of the individual pieces of beam data. Each individual
beam can be processed and transferred as a bit independent of measurement field length, resolution and
beam mode.
Example for the limitation of the measurement field length:
• Resolution of 5 mm: Measurement field length up to 1280 mm
Integration time
74
3
(bit
offset
= 0)
unsigned 8
RW
0 … 65535
0
All measurement values are accumulated and
retained over the duration of the integration time.
Hold function in ms.
Key lock and display
78
0
unsigned 8
RW
0 … 2
0
Lock operational controls on the device.
0: Enabled
1: Locked
2: Volatile
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
The process data settings describe the cyclically transmitted process data.
NOTICE
A maximum of 256 beams can be processed as a bit!
The IO-Link specification only permits 32 bytes as process data; i.e., up to 256 beams can each be
processed and transmitted as a bit.
Through the limitation of the process data length, the beams, depending on the resolution, can only
be processed and transmitted up to a certain measurement field length as a bit.
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Process data settings
72
0
record
128 bit
RW
Evaluation function
module 01
72
(bit
offset
= 120)
1
unsigned 8
RW
1 … 111,
0,
200 … 205,
208 … 210,
212
204
1 … 111: Number of optical cascades for beam-
stream evaluation (16 beams)
0: No function (NOP)
200: First interrupted beam (FIB)
201: First not interrupted beam (FNIB)
202: Last interrupted beam (LIB)
203: Last not interrupted beam (LNIB)
204: Total of interrupted beams (TIB)
205: Total of not interrupted beams (TNIB)
208: Switching state of areas 16 … 1
209: Switching state of areas 32 … 17
210: Switching state of the outputs mapped to the
areas
212: CML 700i status information
Evaluation function
module 02
72
(bit
offset
= 112)
2
unsigned 8
RW
1 … 111,
0,
200 … 205,
208 … 210,
212
202
1 … 111: Number of optical cascades for beam-
stream evaluation (16 beams)
0: No function (NOP)
200: First interrupted beam (FIB)
201: First not interrupted beam (FNIB)
202: Last interrupted beam (LIB)
203: Last not interrupted beam (LNIB)
204: Total of interrupted beams (TIB)
205: Total of not interrupted beams (TNIB)
208: Switching state of areas 16 … 1
209: Switching state of areas 32 … 17
210: Switching state of the outputs mapped to the
areas
212: CML 700i status information