Starting up the device - Configuration
Leuze electronic
BCL 604i
93
Parameter
Table 10.54:
Parameters for module 80
Parameter length
3 byte
Input data
None
Output data
None
10.14 Reference code comparison
The following modules can be used to support reference code comparison.
The reference code function compares the currently decoded read results with one or more stored compar
-
ison patterns. The function is split into two comparison units which can be configured independently of
each other.
10.14.1Module 81 – Reference code comparator 1
Description
The module defines the mode of operation of reference code comparator 1.
Parameter
Description
Addr.
Data type Value range
Default Unit
Sort criterion 1
Specifies the criterion according to
which sorting takes place.
0.0 …
0.6
BitArea
0: No sorting
1: Sorting according to scan number
2: Sorting according to position in the scanning
beam
3: Sorting according to the oscillating mirror posi
-
tion
4: Sorting according to the decoding quality
5: Sorting according to the bar code length
6: Sorting according to the code type number
7: Sorting according to the decoding direction
8: Sorting according to the bar code content
9: Sorting according to time
10: Sorting according to scanning duration
11: Sorting according to the code list (in which the
enabled bar codes are listed)
12: Sorting according to the identifier list
0
-
Sort direction 1
Specifies the sorting direction.
0.7
Bit
0: In ascending order
1: In descending order
0
-
Sort criterion 2
Specifies the criterion according to
which sorting takes place.
1.0 …
1.6
BitArea
See sorting criterion 1
0
-
Sort direction 2
Specifies the sorting direction.
1.7
Bit
See sorting direction 1
0
-
Sort criterion 3
Specifies the criterion according to
which sorting takes place.
2.0 …
2.6
BitArea
See sorting criterion 1
0
-
Sort direction 3
Specifies the sorting direction.
2.7
Bit
See sorting direction 1
0
-