Starting up the device - Configuration
Leuze electronic
BCL 604i
86
10.12.5Module 70 – Switching input/output SWIO1
Parameter
Table 10.48:
Parameters for module 70 – Input/Output 1
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Function
This parameter defines whether I/O 1 func
-
tions as an input or as an output.
0.0
Bit
0: Input
1: Output
0
-
Mode of operation for configuration as an output
DC bias level
The parameter defines the DC bias level of the
switching output and, thus, simultaneously
whether the output is low-active (0) or high-
active (1).
0.1
Bit
0: LOW (0V)
1: HIGH (+Ub)
0
-
Reserved
Free
0.2 … 0.7
Start-up delay
With this parameter, the output pulse may be
delayed by a set time period.
1
UNSIGNED16 0 … 65535
0
ms
Switch-on time
The parameter defines the switch-on time
period for the switching output. If the value is
0, the signal is static.
3
UNSIGNED16 0 … 1300
400
ms
Switch-on function
1
This parameter specifies an event which can
set the switching output.
5
UNSIGNED8
0
-
Switch-on function
2
This parameter specifies an event which can
set the switching output.
Switch-on function 1 and switch-on function 2
are OR linked.
6
UNSIGNED8
0
-
Switch-off function
1
This parameter specifies an event which can
reset the switching output.
7
UNSIGNED8
0
-
Switch-off function
2
This parameter specifies an event which can
reset the switching output.
Switch-off function 1 and switch-off function 2
are OR linked.
8
UNSIGNED8
0
-
Comparative value
(Event Counter)
If the number of activation events of the
selected switch-on function reaches this com
-
parative value, the switching output is acti
-
vated. A deactivation event of the selected
switch-off function resets the counter.
9
UNSIGNED16 0..65535
0
-
Compare mode
(Event Counter)
Specifies whether the switching output
switches only on parity (once) or also in the
event of greater or equal to (multiple times)
after the comparative value is reached.
11
UNSIGNED8
0: SWOUT switches once
1: SWOUT switches sev
-
eral times
0
-
Reset mode
(Event Counter)
Specifies whether the counter (Event Counter)
is reset only by the reset bit and the selected
switch-off function, or if the counter should be
automatically reset after the comparative value
is reached.
12
UNSIGNED8
0: Reset bit and switch-off
funct.
1: Comparative value
reached
0
Mode of operation for configuration as an input
Inversion
The parameter defines the logic of the incident
signal. In case of an inversion, an external
HIGH level is interpreted internally as a LOW
level.
13.1
Bit
0: Normal
1: Inverted
0
-
Reserved
Free
13.2 … 13
.7
Debounce time
The parameter defines a debounce time which
is implemented in software.
14
UNSIGNED16 0 … 1000
5
ms
Start-up delay
The parameter influences the timing during
switch-on.
16
UNSIGNED16 0 … 65535
0
ms