Device description
Leuze electronic
BCL 604i
17
NET LED
3.6
Operational controls
Navigating within the menus
Use the navigation buttons
to move through the menu. Activate the desired selection with the enter
button .
Press the escape button to move up one menu level.
When one of the buttons is actuated, the display illumination is activated for 10 min.
Setting values
Set the desired value with the navigation buttons
and the enter button .
An accidental incorrect entry can be corrected by selecting the left arrow button and then pressing the
enter button.
Then use the navigation buttons to select save and save the set value by pressing the enter button.
Selecting options
Set the desired option with the navigation buttons
and the enter button .
Orange, continu
-
ous light
Service mode
• Bar code reading possible
• Configuration via the USB service interface
• Configuration via the display
• No data on the host interface
Flashes red
Device ok, warning set
• Bar code reading possible
• Temporary operating fault
Red, continuous
light
Device error / parameter enable
• No bar code reading possible
Off
No supply voltage
• No communication possible
• Profibus DP communication not initialized or inactive
Flashes green
Initialization
• of the device, establishing communication
Green, continu
-
ous light
Operation OK
• Network mode ok
• Connection and communication to IO controller (PLC) established (data
exchange)
Flashes red
Communication error
• Parameterization or configuration failed (parameter failure)
• IO error
• No data exchange
Red, continuous
light
Network error
• No communication (protocol) to IO controller established (no data exchange)