PROFIBUS
Leuze electronic
BCL 34
63
TNT
35/7-2
4
V
8.3.13
AutoControl
Module 16
The module defines the mode of operation of the function AutoControl. The function moni-
tors the quality of the decoded barcodes and compares these with a limit value. If the limit
is reached, a status signal is set.
Parameters
Input Data
Output Data
none
Parameter
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Mode
The parameter defines the evaluation base of the Auto-
Control function. Depending on the setting, either the
label quality or the decoding quality can be used as cri-
teria for the reading quality.
The label quality is the ratio between the scans which
have collected information for the decoding, and the
number of scans which were necessary to decode the
entire barcode.
Label quality =
The decoding quality is computed as follows: ratio
between the identical scans and the number of scans
which were necessary to decode the entire barcode.
Decoding quality =
0: Off
1: Label quality
2: Decoding quality
0
–
Limit for
reading
quality
The parameter defines a threshold value for the average
of the reading quality. If the value is not reached, a
warning is generated.
0 … 100
50
%
Sensitivity
With this parameter the insensitivity towards changes in
the reading ability can be specified. The higher the
value, the less influence a change of reading ability has
on the floating average.
0 … 255
0
–
Parameter length: 3 bytes
a
Scans with information per
barcode
Scans per barcode
Identical scans
Scans per barcode
b
c
Input Data
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
AutoControl
status
Signal indicates the state of the AutoControl function
0.0
Bit
0: Off
1: On
0
–
AutoControl
result
Signal indicates whether the result of the AutoControl
function was a good or bad reading. A bad reading
quality has occurred if the limit defined in module 16
was not reached.
0.1
Bit
0: Quality good
1: Quality bad
0
–
16b
Scan quality
This value is the current average of the scan quality.
1
unsign8 0 … 100
0
–
Input data length: 2 byte