PROFIBUS
58
BCL 34
Leuze electronic
8.3.9
Data Formatting
Module 12
The module defines the output string for the case that the BCL could not read a barcode.
In addition, the initialisation of the data fields and the definition of unused data ranges may
be set.
Parameters
Input Data
none
Output Data
none
Parameter
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Text in the
case of
misreading
The parameter defines the output characters if
no barcode could be read.
1 … 20 bytes of ASCII
characters
63 ("?")
–
20g or
21…27g
Decoding
result at read-
ing gate start
The parameter defines the state of the data at
the start of the reading gate.
0: Input data remain on
the old value
1: Input data are reset to
the init value 0
0
–
Data
alignment
The parameter defines the alignment of the data
in the result field
0: Left-justified
1: Right-justified
0
–
Fill mode
The parameter defines the fill mode for the
unoccupied data ranges
0: No alignment
3: Fill up to the transmis-
sion length
3
–
12e
Fill character
The parameter defines the character which is
used for filling up the data areas.
0 … 255
45 ("-")
–
12d
Parameter length: 23 bytes