PROFIBUS
Leuze electronic
BCL 34
45
TNT
35/7-2
4
V
8.1.1
GSD File
The GSD file can be found on the disc supplied with this documentation. It is named
Leuz05d8.GSD.
This file stores all the data required for the operation of the BCL 34. These are device
parameters for reading barcodes, PROFIBUS operation parameters, and the definition of
the control and status bits. If parameters are changed in the project, for example, these
changes are stored in the project, not in the GSD file.
The GSD file is a certified part of the device and must not be changed manually. The file is
not changed by the system either.
8.1.2
Permanently defined parameters (device parameters)
On the PROFIBUS, parameters may be stored in modules or may be defined permanently
in a PROFIBUS participant.
The permanently defined parameters are called "common" parameters or device-specific
parameters, depending on the project tool.
Hilscher Master Controller
In SyCon, the permanently defined parameters are set via "slave configuration"
Ö
"parameter data"
Ö
"common".
The module parameters are set via "slave configuration"
Ö
"parameter data"
Ö
"module".
Simatic S7 Controller
In Simatic Manager, the permanently defined parameters are set via object properties of
the device.
The module parameters are set via the module list of the selected device. By selecting the
project properties of a module, the respective parameters may be set if required.
The permanently defined parameters in the BCL 34 which are available independently of
the modules, are listed below.
Notice!
In the following detailed descriptions of the modules you will find
cross references (CR) to
device parameters (#) and to parameters and input/output data of other modules
in
the last column of the tables. These are directly related to the parameter described. These
cross references must be observed during configuration.
The individual
modules
are
numerically
labelled from
1 … 50
.
The
parameters and input/output data
within a module are
alphanumerically labelled
from …
.
a
z
Summary of Contents for BCL34
Page 1: ...BCL34 Barcode reader GB 05 10 08 50038851 T E C H N I C A L D E S C R I P T I O N...
Page 98: ...Appendix 96 BCL 34 Leuze electronic 12 Appendix 12 1 EU Declaration of Conformity...
Page 102: ...Index 100 BCL 34 Leuze electronic V Vibration 18 W Warm up time 18 Warning notices 8 Weight 17...