Installation
Leuze electronic
BCL 34
35
TNT
35/7-2
4
V
7.2.1
Arrangement of devices
Selecting a mounting location
In order to select the right mounting location, several factors must be considered:
• Size, orientation, and position tolerance of the barcodes on the objects to be
scanned.
• The reading field of the BCL 34 in relation to the barcode module width.
• the resulting minimum and maximum reading distance from the respective reading
field
For specific information, please refer to chapter 5.4.
Notice!
The best reading results are obtained when
• the barcode is moved in a plane that is parallel to the reading window
• the reading distance lies in the middle area of the reading field
• you do not use high-gloss labels.
Notice!
On the BCL 34, the beam is not emitted perpendicular to the cover of the housing, but with
an angle of 10° towards the top. This angle is intended in order to avoid a total reflection of
the laser in the case of glossy labels. For highly reflective surfaces, this angle may be wid-
ened by tilting the BCL.
Figure 7.3:
Beam exit on BCL 34
103 ± 2
10˚
Minimum reading dis-
tance, depending on the
optical system used
(see reading curves)
Light
e
x
it
all dimensions in mm