Accessories/order codes
Leuze electronic GmbH + Co. KG
BCL 8
23
5.3
Connection unit MA 8-01
The modular connection unit is an optional accessory when connecting a BCL 8 to an RS 485 interface.
The RS 485 interface, the switching input and the switching output are all connected to the MA 8-01. It also
supplies voltage to the BCL 8. The MA 8-01 connection unit offers the following advantages over the instal
-
lation of the BCL 8 as a stand-alone device:
• M12 socket for switching input and switching output
• M12 connector for RS 485 interface and voltage supply 24VDC
• M12 socket for connection of the BCL 8
Figure 5.7: Pin assignment - MA 8
-
01
Electrical connection MA 8-01
ATTENTION!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into place!
Electrical data
Interface type
RS 485
Service interface
No MA 8
-
01 connected:
RS 232 with default data format,
9600Bd, 8 data bits, no parity, 1 stop bit
With MA 8
-
01 connected:
RS 485 replaces RS 232
Switching input/output
1 switching input, 1 switching output, each is programmable
Switching input: 10 … 30VDC
Switching output: I
max
= 500mA
Output voltage = operating voltage
Operating voltage
10 … 30VDC
Power consumption
Max. 0.5W
PWR IN HOST/RS485
= Voltage supply/RS 485 host interface
SW IN/OUT
= Switching input/output
BPS
= Connection to BCL 8/BPS 8
Note!
The SW IN/OUT connection is sealed with a thread plug upon delivery.
all dimensions in mm
1
2
3
4
5
RXD
VIN
GND
SWIN/SWOUT
TXD
1
2
3
4
5
SWIN
VOUT
GND
FE
SWOUT
3
2
1
4
5
A (P)
GND
VIN
FE
B (N)
BPS
SW IN/OUT
PWR IN
HOST/RS485
M12 socket
(A-coded)
M12 socket
(A-coded)
M12 connector
(A-coded)