Commissioning and configuration
Leuze electronic GmbH + Co. KG
BCL 358
i
85
10.7.2.2
Output assembly
The output assembly is the cyclical data from the control to the BCL 358
i
. The following output assemblies
are supported.
Output assembly instance 120
Instance 120, attribute 3
Output assembly, length
min. 1 byte
max. 263 bytes
The number of data starting at byte 8 is defined in the control while configuring the BCL 358
i
. This makes
it possible to use the assembly with any length.
It is also possible to specify the length of the assembly with one byte and thereby only use the control bits.
With a length of 2 bytes, the I/O monitoring control bits can be used in addition to the control bits.
Inst.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
120
0
Reserved
Standby
Error
acknowl
-
edge
Data
reset
Data
acknowledg
-
ment
Activation
signal
1
Reserved
Reset Event
Counter
2
Activation
switching
output 2
1)
1) To be able to use the Activation switching output function, the output function must be set to External event in webCon
-
fig.
Reset Event
Counter
1
Activation
switching
output 1
1)
2
Fragment number (see chapter 10.7.6 "Class 108 - Entry data")
3
Remaining fragments (see chapter 10.7.6 "Class 108 - Entry data")
4
Fragment size (see chapter 10.7.6 "Class 108 - Entry data")
5
Reserved
New
entry
(toggle bit)
New
data
6
Entry data length (low byte)
7
Entry data length (high byte)
8
Data Byte 0
9
Data Byte 1
…
…
262
Data Byte 254
NOTE
The use of the assembly is illustrated with examples at the end of this chapter.
NOTE
Formula for calculating the assembly length:
Length of the assembly = 8 + length of the entry data
For entry data with length 10, the assembly must be configured with a length of 8 + 10 = 18.