Commissioning and configuration
Leuze electronic GmbH + Co. KG
BCL 358
i
79
10.4 Configuration steps for a Rockwell control without EDS support
10.4.1 Integrating the hardware into the PLC using the generic Ethernet module
In the RSLogix 5000 configuration tool (up to software version 20.00), a so-called generic Ethernet module
is created under the Communication path for the BCL 358
i
.
Figure 10.2: Generic Ethernet module
The input mask for the generic module describes the following parameters to be set:
• The name of the participant (can be selected freely; e.g. BCL 358
i
)
• The format of I/O data (data - SINT = 8 bits)
• The IP address of the participant
• The address and length of the input assembly (instance 100, instance 101 or instance 102; min 1
byte - up to max. 266 bytes for the default input assembly of the read results).
• The address and length of the output assembly (instance 120, instance 121 or instance 122; min 1
byte - up to max. 263 bytes for the default output assembly)
• The address and length of the configuration assembly (instance 190; 3 bytes)