Fast commissioning / operating principle
Leuze electronic GmbH + Co. KG
BCL 358
i
17
Configuration of the participant using the EDS file
From software version 20.00 and up, proceed as follows in the RSLogix 5000 configuration tool to create
the BCL 358
i
as an EtherNet/IP participant in your system:
• First, load the EDS file for the device via EDS wizard into the PLC database.
• After it has downloaded, select the device from the device list.
• Open the input dialog for setting the address and additional parameters by double-clicking on the
device symbol and make the desired entries here.
• Finally, transmit the values to the control via download.
3.4.4 Transferring the data to the control (RSLogix 5000 specific)
• Activate the online mode
• Select the Ethernet communication port
• Select the processor onto which the project is to be transferred
• Set the control to PROG
• Start the download
• Set the control to RUN
3.5
Further settings
After the basic configuration of the operating mode and the communication parameters, you need to carry
out further settings:
• Decoding and processing the read data
Define at least one code type with the desired settings.
•Via webConfig:
Configuration -> Decoder
• Control of the decoding
Configure the connected switching inputs according to your requirements. To do this, first set the
I/O mode
to
Input
and then configure the switching behavior:
•Via webConfig:
Configuration > Device > Switching inputs/outputs
• Control of the switching outputs
Configure the connected switching outputs according to your requirements. To do this, first set the
I/O mode
to
Output
and then configure the switching behavior:
•Via webConfig:
Configuration > Device > Switching inputs/outputs
NOTE
You can find the EDS file at: www.leuze.com.