Technical data
Leuze electronic GmbH + Co. KG
ELC 100
36
12
Technical data
12.1
General specifications
Tab. 12.1:
Protective field data
Physical resolu-
tion [mm]
Operating range [m]
Protective field height [mm]
min.
max.
min.
max.
17
0.5
3
300
1500
30
0.5
6
300
1500
Tab. 12.2:
Safety-relevant technical data
Type in accordance with IEC/EN IEC 61496
Type 4
SIL in accordance with IEC/EN 61508
SIL 3
SILCL in accordance with IEC/EN 62061
SIL 3
Performance Level (PL) in accordance with ISO/EN ISO 13849-1:2015
PL e
Category in acc. with ISO/EN ISO 13849-1:2015
Cat. 4
Average probability of a failure to danger per hour (PFH
d
)
8 x 10
-9
1/h
Mission time (T
M
)
20 years
Tab. 12.3:
General system data
Connection technology
M12, 4‑pin
Supply voltage U
v
, transmitter and receiver
+24 V, ± 20 %, compensation necessary at 20 ms
voltage dip, min. 250 mA (+ OSSD load)
Residual ripple of the supply voltage
± 5 % within the limits of U
v
Current consumption - transmitter
40 mA
Current consumption receiver
100 mA (without load)
Common value for ext. fuse in the supply line for
transmitter and receiver
2 A semi time-lag
CULus range of validity
Connection with cables acc. to the listed R/
C (CYJV2/7 or CYJV/7) cables or cables with corre-
sponding data.
Synchronization
Optical between transmitter and receiver
Protection class
III
Degree of protection
IP65
Ambient temperature, operation
0 … 50 °C
Ambient temperature, storage
-30 … 70 °C
Relative humidity (non-condensing)
0 … 95 %
Vibration/shock resistance
Class 3M4 (IEC TR 60721-4-3)
Vibration resistance
5 Hz … 150 Hz; 3.5 mm/1g (IEC 60068-2-6)
Shock resistance
15 g, 6 ms (IEC 60068-2-27)
In addition to the tests in accordance with
IEC 60068-2-27, the safety light curtain was subject
to additional continuous shock tests. The devices
withstood 100000 shocks of 40 g on each spatial
axis without change.
Profile cross section
29 mm x 35.4 mm