User Interface
Leuze electronic GmbH + Co. KG
LCAM 308
20
RTSP path
<empty>
0-30 characters, a-z,
A-Z, 0-9
Path segment of RTSP URI
RTSP port
8554
554, 8554
RTSP port
Recording
Pre-event
recording time [s]
10
1-60
Recording time before the trigger point
Post-event
recording time [s]
10
1-60
Recording time after the trigger point
Recording stream
resolution
640x360
1920 x 1080,
1280 x 720, 1024 x 576,
960 x 540, 800 x 450,
640 x 360
Recording stream resolution
Recording stream
quality
50
0-100%
Recording stream quality
Delete oldest
when memory is
full
active
Deletes the oldest videos if necessary.
Access
admin user name admin
1-255 characters
User name for admin user
admin password <empty>
1-50 characters
The password for the user admin.
Password protection can be disabled
viewer user name viewer
1-255 characters
User name for viewer user
viewer password <empty>
1-50 characters
The password for the user viewer.
Password protection can be disabled
Network
IP address
192.168.60.101
IPv4 address
The IPv4 address of the camera. If
DHCP is enabled, this is used as
fallback.
Netmask (CIDR) 24
0-30
Net mask in CIDR notation
Gateway IP
address
<empty>
IPv4 address, optional
The gateway is required if the NTP
server is in another subnet.
DNS server IP
address
<empty>
IPv4 address, optional
DNS server, currently not required
DHCP
active
Enables DHCP. If no DHCP server is
available, the camera uses the set IP
address as static address.
NTP server
address
<empty>
IPv4 address, optional
NTP server. Is required to set the
camera time.
Timezone
Europe/Berlin
Camera timezone for local time in
overlay and recordings
Setting
Default
Input restriction
Description
Table 6.1:
Camera