Mounting and connecting
Leuze electronic GmbH + Co. KG
LCAM 308
13
4
Mounting and connecting
CAUTION
The camera must be installed using the M6 female threads in the mounting socket (see draw
-
ing). No other type of mounting is permitted.
CAUTION
Fasteners that are screwed into the M6 female threads may be tightened depending on the
manufacturing date to a maximum torque of 1 Nm (from manufacturing date 10/2020).
CAUTION
The camera must be fastened regarding the operating conditions. The mounting must be
checked and maintained at regular intervals.
NOTICE
For a vibration-resistant screw connection, we recommend screw locking lacquer, e.g. Loctite
243 from Henkel.
CAUTION
The two electrical connections of the camera must also be made with M12 connectors, includ
-
ing mechanical locking via the M12 threads, according to the connectors of the camera. These
mechanical interlocks must be hand-tightened after plugging in the connection cables. The
fastening of the connections must be carried out in accordance with the operating conditions
and conditions of use and, if necessary, checked and repaired regularly so that they do not
become loose over time.
CAUTION
When selecting the connecting cables, the information in this manual and the data sheet for
the camera, especially with regard to the electrical specifications, have to be taken into
account.
CAUTION
The electrical connection of the camera must not be established until the mounting according
to the specifications has been carried out.