Diagnostics and troubleshooting
Leuze electronic GmbH + Co. KG
BCL 208i
55
11
Diagnostics and troubleshooting
11.1
Error signaling via LED
Tab. 11.1:
Meaning of the LED indicators
Error
Possible error cause
Measures
PWR LED
Off
• No supply voltage connected to
the device
• Hardware error
• Check supply voltage
• Contact Leuze customer service (Service
and support)
Red, continuous
light
Device error/parameter enable
Contact Leuze customer service (Service and
support)
Red, flashing
Warning set
Temporary operating fault
Query diagnostic data and carry out the result-
ing measures
Orange, continu-
ous light
Device in Service mode
Reset Service mode with webConfig tool
NET LED
Off
• No supply voltage connected to
the device
• Ethernet host communication not
yet activated
• Hardware error
• Check supply voltage
• Activate Ethernet host communication
• Contact Leuze customer service (Service
and support)
Red, continuous
light
No communication
• Check interface
Red, flashing
• Communication error
• Check interface
11.2
Interface error
Tab. 11.2:
Interface error
Error
Possible error cause
Measures
No communication
via the Ethernet in-
terface
• Incorrect wiring
• Different protocol settings
• Protocol not released
• Check wiring
• Check protocol settings
• Activate TCP/IP or UDP
Sporadic errors at
the Ethernet inter-
face
• Incorrect wiring
• Effects due to EMC
• Overall network expansion ex-
ceeded
• Check wiring
• In particular, check wire shielding
• Check the cable used
• Check shielding (shield covering in
place up to the clamping point)
• Check grounding concept and connec-
tion to functional earth (FE)
• Avoid EMC coupling caused by power
cables laid parallel to device lines.
• Check max. network expansion as a
function of the max. cable lengths