Technical data
Leuze electronic GmbH + Co. KG
BCL 308
i
35
5.2.3 Line scanner / raster scanner with deflecting mirror and heating
Technical data same as for line scanner without heating, however with the following differences:
Type
BCL 308
i
Ethernet
Design
Deflecting mirror scanner with heating
Optical data
Useful opening angle
Max. 60°
Max. adjustment range
±10 °(adjustable via display or software)
Electrical data
Operating voltage
24 V DC ± 20%
Power consumption
Max. 19.7 W
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30 min at +24 V DC and an ambient temperature of -35 °C
Min. conductor cross
section
Conductor cross section of at least 0.75 mm² for the supply-voltage line.
Wiring through of the voltage supply to multiple heating devices is not permissible.
Standard, M12 ready-made cable not usable (insufficient cable cross-section)
Environmental data
Operating temperature
range
-35 °C … +40 °C
Storage temperature
range
-20 °C … +70 °C
Table 5.7:
Technical data of the BCL 308
i
deflecting mirror scanners with heating