Technical data
Leuze electronic GmbH + Co. KG
BCL 308
i
34
Power consumption
The energy requirement depends on the model:
• the line/raster scanner with heating consumes a maximum of 27 W power.
• the line scanner with oscillating mirror and heating consumes a maximum of 45 W.
• the line/raster scanner with deflecting mirror and heating consumes a maximum of 27 W power.
These values are based on operation with unconnected switching outputs.
5.2.1 Line scanner / raster scanner with heating
Technical data same as for line scanner without heating, however with the following differences:
5.2.2 Oscillating-mirror scanner with heating
Technical data same as for line scanner without heating, however with the following differences:
ATTENTION!
The voltage supply must not be looped through from one device to the next.
Type
BCL 308
i
Ethernet
Design
Line scanner with heater
Electrical data
Operating voltage
24 VDC ± 20 %
Power consumption
Max. 17.7 W
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30 min at +24 V DC and an ambient temperature of -35 °C
Min. conductor cross
section
Conductor cross section of at least 0.75 mm² for the supply-voltage line.
Wiring through of the voltage supply to multiple heating devices is not permissible.
Standard, M12 ready-made cable not usable (insufficient cable cross-section)
Environmental data
Operating temperature
range
-35 °C … +40 °C
Storage temperature
range
-20 °C … +70 °C
Table 5.4:
Technical data of the BCL 308
i
line / raster scanners with heating
Type
BCL 308
i
Ethernet
Design
Oscillating-mirror scanner with heating
Optical data
Useful opening angle
Max. 60°
Max. swivel angle
±20° (adjustable)
Electrical data
Operating voltage
24 V DC ± 20%
Power consumption
Max. 26.7 W
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30 min at +24 V DC and an ambient temperature of -35 °C
Min. conductor cross
section
Conductor cross section of at least 0.75 mm² for the supply-voltage line.
Wiring through of the voltage supply to multiple heating devices is not permissible.
Standard, M12 ready-made cable not usable (insufficient cable cross-section)
Environmental data
Operating temperature
range
-35 °C … +40 °C
Storage temperature
range
-20 °C … +70 °C
Table 5.6:
Specifications of the BCL 308
i
oscillating-mirror scanners with heating