Fast commissioning / operating principle
Leuze electronic GmbH + Co. KG
BCL 308
i
20
3.6
Starting the device
Connect the +18 … 30 V DC supply voltage (typ. +24 V DC).
The BCL 308
i
starts up, the PWR and NET LEDs display the operating state. If there is a display, the bar
code reading window appears in it.
PWR LED
Green, continuous light
Power On, device OK
Green, briefly off - on
Good read, successful reading
Green, briefly off -
briefly red - on
No read, reading not successful
Orange, continuous light
Service mode
Red, flashing
Warning set
Red, continuous light
Error, device error
NET LED
Flashes green
Initialization
Green, continuous light
Network operation OK
Flashes red
Communication error
Red, continuous light
Network error
LED ACT0 / LINK0 (on the MS 308/MK308)
Green, continuous light
Ethernet connected (LINK)
Yellow, flickering light
Data communication (ACT)
LED ACT1 / LINK1 (on the MS 308/MK308)
Green, continuous light
Ethernet connected (LINK)
Yellow, flickering light
Data communication (ACT)
If a display is available, the following information appears successively during startup:
•
Startup
• Device designation e.g.
BCL 308i SM 102 D
•
Reading Result
If
Reading Result
is displayed, the device is ready.