Fast commissioning / operating principle
Leuze electronic GmbH + Co. KG
BCL 308
i
16
MK 308 terminal hood with spring-cage terminals
Figure 3.5: BCL 308
i
- MK 308 terminal hood with spring-cage terminals
Cable fabrication and shielding connection
Remove approx. 78 mm of the connection cable sheathing. 15 mm of sheath of the shielded line must be
freely accessible.
Figure 3.6: Cable fabrication for MK 308 terminal hood
The shield is automatically contacted when the cable is lead into the metal screw fitting and fastened when
the cord grip is closed. Then lead the individual wires into the terminals according to the diagram. Wire end
sleeves are not necessary.
3.4
Preparatory settings – Ethernet
Connect the +18 … 30 V DC supply voltage (typ. +24 V DC); the BCL 308
i
starts up.
As a first step, you need to set the communication parameters of the BCL 308
i
. You can make the neces
-
sary settings via the webConfig tool. Further information can be found in Chapter 10.
3.4.1 Manual configuration of the IP address
If your system does not include a DHCP server or if the IP addresses of the devices are to be set perma
-
nently, proceed as follows:
Have the network administrator specify the data for IP address, net mask and gateway address of the
BCL 308
i
.
Set these values on the BCL 308
i
:
NOTE
The integrated parameter memory for the simple replacement of the BCL 308
i
is located in the
MK 308. In the integrated parameter memory, both the settings and the network address are
saved and transmitted to a new device.
NOTE
In the case of Ethernet linear topology, the network is interrupted when the BCL 308
i
is removed
from the MK 308.
Terminal hood
MK 308
SERVICE
2
1
3
5
4
GND
D+
D-
VB
ID
Mini-B USB socket
(behind protective
cap)
Te
rmi
nal bl
ock
PW
R /
SW
IN/O
UT
Te
rmi
nal bl
ock
HOST
/
BUS IN
(Ethernet 0
)
Terminal designation
MK 308
Te
rmi
nal bl
ock
BUS OUT
(Ethernet 1
)
Ethernet 1 LED
(split, two-colored):
ACT1 / LINK1
Ethernet 0 LED
(split, two-colored):
ACT0 / LINK0
LEDs
MK 308
≈ 55 mm
≈ 8 mm
≈ 15 mm