Interbus interface
Leuze electronic GmbH + Co. KG
AMS 384
i
55
TNT
35/7-2
4V
Continuing participants connected via BUS OUT are addressed even if the Interbus is deac
-
tivated.
9.5.1
Default settings of the Interbus interface
Table 9.3:
Default settings of the Interbus interface
Note!
The AMS 384
i
cannot be configured via the Interbus.
The settings marked with footnote 1) can be changed via the display. Changed parameters
are saved in the AMS 384
i
and reactivated after power ON/OFF.
Default parameters of AMS 384
i
xxx (H)
Interbus activation
1)
NF
m~ê~ãÉíÉê=Å~å=ÄÉ=ÅÜ~åÖÉÇ=îá~=Åçåíêçä=é~åÉäLÇáëéä~ó
ON
Baud rate
500kbit/s
Ident code
32H
Number of data bits
32
Data distribution
23 bits for measurement value, 1 bit for sign, 2 bits for reserve, 3 bits for pre
-
failure messages,
2 bits for error, 1 bit for static to binary 1
Measurement value display
1)
Gray
Unit
1)
Metric
Resolution
1)
1mm
Counting direction
1)
Positive
I/O 1
1)
Input LOW = Laser ON, HIGH = Laser OFF
I/O 2
1)
Velocity monitoring output set to > 0.2 m/s (configurable)
Static preset
1)
+ 000,000
Dynamic preset
1)
+ 000,000
Pos. limit value range 1
1)
Lower limit and upper limit, both 000,000
Pos. limit value range 2
1)
Lower limit and upper limit, both 000,000
Error handling procedures
1)
Position output: 000,000
Position status suppression: active
Position error delay time: 100 ms
Display language
1)
English
Display illumination
1)
OFF after 10min.
Display contrast
1)
Medium
Password protection
1)
Off
Password
1)
0000